<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>20-oji konferencija „Pastatų inžinerinės sistemos“ (2017) / 20th Conference "Engineering systems for building" (2017)</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/156832" rel="alternate"/>
<subtitle/>
<id>https://etalpykla.vilniustech.lt/handle/123456789/156832</id>
<updated>2026-04-05T18:34:32Z</updated>
<dc:date>2026-04-05T18:34:32Z</dc:date>
<entry>
<title>Ugdymo įstaigų patalpų oro kokybės analizė</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/156949" rel="alternate"/>
<author>
<name>Ždanovskis, Egidijus</name>
</author>
<author>
<name>Šiupšinskas, Giedrius</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/156949</id>
<updated>2025-03-24T11:44:46Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Ugdymo įstaigų patalpų oro kokybės analizė
Ždanovskis, Egidijus; Šiupšinskas, Giedrius
21jo amžiaus visuomenė pasirinko darnaus vystymosi kelią. Daug dėmesio skiriama sveikai aplinkai kurti, palankaus gyvenimo būdui formuoti. Patalpų komfortui turi įtakos ne tik oro temperatūra, bet ir santykinė drėgmė, švie žio oro kiekis ir jo apykaita, CO2 koncentracija ir kiti parametrai. Tik atsižvelgus į juos, galima tiksliai apibūdinti patalpų mikroklimato būklę ir higienos normų atitiktį. Taigi šiam tikslui Vilniaus mieste yra pasirinktos 4 ugdymo įstaigos (vaikų darželiai), kurioms remiantis Lietuvos statybos ir higienos normose apibrėžtais reikalavimais ir pateiktomis rekomendaci jomis, yra atliekama patalpų oro kokybės analizė. Remiantis eksperimentiniais tyrimo duomenimis, siekiama  nustatyti esamas ugdymo įstaigų esamas problemas, pasiūlyti technologinius sprendinius ir rekomendacijas, kaip jose pagerinti mikroklimato parametrus ir užtikrinti, kad pasirinktas sprendinys atitiktų norimus poreikius.; 21st century society has chosen the path of sustainable&#13;
development. Much attention is paid to creating a healthy environment,&#13;
friendly lifestyle formation. Indoor comfort affects not&#13;
only the temperature, but also the relative humidity of fresh air&#13;
and it’s circulation, CO2 concentration. Only in the light of&#13;
them, can be accurately describe the condition of indoor climate&#13;
and hygiene standards compliance. So, for this purpose in Vilnius&#13;
are selected 4 educational institutions (kindergartens),&#13;
which is performed in indoor air quality analysis, based on the&#13;
Lithuanian construction and sanitary norms defined requirements&#13;
and recommendations. Based on the experimental study,&#13;
it will be possible to establish educational institutions existing&#13;
problems, offer technological solutions, guidance as they improve&#13;
the microclimate parameters and ensure that the chosen&#13;
solution will meet the desired needs.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Išlyginamosios talpos įtaka paukščių skerdyklos nuotekų koaguliacijos / flokuliacijos procesui</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/156948" rel="alternate"/>
<author>
<name>Vaičiūtė, Gintarė</name>
</author>
<author>
<name>Kirjanova, Ala</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/156948</id>
<updated>2025-03-24T11:43:41Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Išlyginamosios talpos įtaka paukščių skerdyklos nuotekų koaguliacijos / flokuliacijos procesui
Vaičiūtė, Gintarė; Kirjanova, Ala
Paukščių skerdyklų nuotekų, kaip ir daugumos gamybinių nuotekų, sudėtis ir srautas per parą labai netolygūs, dėl šios priežasties prieš flotatorius paprastai įrengiamos išlyginamosios talpos. Pasak įmonės „EKOTON“ specialistų, rekomenduojama nuotekų išbuvimo išlyginamosiose talpose, kur jos nuolat maišomos maišykle, trukmė – 2–4 valandos. Tačiau realiai pasitaiko atvejų, kai į flotatorių tiekiamos nuotekos, neišbuvusios išlyginamojoje talpoje net minimalaus rekomenduojamo laiko, dėl to pastebimai suprastėja nuotekų išvalymo efektyvumas flotatoriuje. Eksperimentų metu tam tikrais laiko intervalais imti nuotekų mėginiai iš dviejų reaktorių, imituojančių maišomą ir aeruojamą išlyginamąsias talpas. Mėginiai buvo koaguliuojami / flokuliuojami, taip imituojant pirmąjį flotacijos proceso etapą, ir po to analizuojami pagal ChDS, BDS7, NH4 , NO 2 , N O3 ir	 PO4P koncentracijas. Organinių medžiagų koncentracijos po koaguliacijos / flo kuliacijos mažėjo ilgėjant nuotekų išbuvimo reaktoriuose trukmei: po pirmos valandos ChDS koncentracija abiejuose re aktoriuose sumažėjo 75 %, o po 8 valandų pradinė ChDS koncentracija maišomame reaktoriuje sumažėjo 83 %, aeruoja mame – 88 %. Azoto ir fosforo junginių atveju išbuvimo trukmė reaktoriuje ir reaktoriaus tipas neturėjo įtakos šių junginių koaguliacijos / flokuliacijos efektyvumui.; The composition and flow of wastewater of poultry slaughterhouse, as well as the majority of industrial wastewater, are very uneven, for this reason, buffer tank is usually installed before flotation unit. Recommended hydraulic retention time in a buffer tank is 2–4 hours while constantly stirring. However, in reality, sometimes fresh wastewater is fed directly to flotation unit, in this case, removal efficiency of pollutant is substantially reduced.  During the experiment, samples were taken at a certain time intervals and concentrations of pollutants (COD, BOD7, NO2-N, NO3-N, NH4-N  and PO4-P) were measured. After coagulation/flocculation organic material concentrations in reactors decreased with retention time: after the first hour COD concentration  in both reactors decreased by 75% and after 8 hours initial COD concentration in mixing reactor decreased by 83%, in aerated reactor – 88%. Retention time in reactors had no impact for nitrogen and phosphorus compounds coagulation/flocculation efficiency.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Daugiabučių namų kvartalo aprūpinimo šiluma alternatyvų analizė</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/156947" rel="alternate"/>
<author>
<name>Stasiulionis, Tomas</name>
</author>
<author>
<name>Biekša, Darius</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/156947</id>
<updated>2025-03-24T11:46:20Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Daugiabučių namų kvartalo aprūpinimo šiluma alternatyvų analizė
Stasiulionis, Tomas; Biekša, Darius
Mažai energijos vartojančiuose pastatuose keičiasi įprastas šilumos energijos balansas – mažėja šilumos dalis patalpoms šildyti ir didėja šilumos poreikis karštam vandeniui ruošti. Norint parinkti šilumos šaltinių galias, reikia atlikti šilumos poreikių analizę ir nustatyti įrangos darbo grafikus. Šiame darbe nagrinėjamos mažai energijos vartojančių dau giabučių namų kvartalo aprūpinimo šiluma alternatyvos. Nustatomas kvartalo šilumos poreikis, parenkami elektrinių ka tilų, centralizuoto šilumos tiekimo, dujinių katilų, šilumos siurblių, granulinių katilų, kogeneracinių katilų ir jų kombinacijų su saulės kolektoriais įrangos galingumai bei akumuliacinių talpų tūriai, taip pat sudaromi šios įrangos vei kimo grafikai. Modeliavimas atliekamas DesignBuilder ir EnergyPRO programomis.; In low energy buildings the heat balance has changed comparing to the typical old buildings. Heat demand for domestic hot water increased and heat demand for space heating decreased. In order to select equipment there is a need to make the heat demand evaluation and the equipment operation schedules. This paper presents investigation of selection heat supply alternatives for nearly zero energy buildings district. The selection of equipment load for electric boilers, gas boilers, district heating, heat pumps, pellet boilers, CHP, flat solar collectors and volume of accumulation tanks are investigated. Created equipment operation schedules. Simulation made with EnergyPRO.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Dumblo tiekimo režimo poveikio dumblo pūdymo procesui tyrimas</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/156946" rel="alternate"/>
<author>
<name>Pakalniškis, Marius</name>
</author>
<author>
<name>Dauknys, Regimantas</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/156946</id>
<updated>2025-03-24T11:45:21Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Dumblo tiekimo režimo poveikio dumblo pūdymo procesui tyrimas
Pakalniškis, Marius; Dauknys, Regimantas
Anaerobinis dumblo stabilizavimas yra vienas plačiausiai pasaulyje taikomų dumblo apdorojimo būdų. Šio proceso metu ne tik sumažinamas dumblo kiekis (iki 50 %), bet ir pašalinamas nemalonus dumblo kvapas bei patogeni niai mikroorganizmai, susidaro šalutinis produktas – biodujos. Anaerobinio pūdymo proceso efektyvumui turi įtakos įvai rūs aplinkos veiksniai ir technologiniai parametrai, vienas jų – dumblo tiekimo režimas. Tyrimu atlikta keturių Lietuvos miestų nuotekų valyklų lyginamoji analizė pagal pirminio ir perteklinio dumblo kokybę, dumblo mišinio proporcinę su dėtį ir aplinkos veiksnius bei technologinius parametrus. Lyginant atrinktų valyklų dumblo pūdymą apibūdinančius ro diklius, nustatyta, kad du kartus trumpesnis dumblo tiekimo į pūdymo grandį ciklas, kai jo metu tiekimo trukmė sudarė 4 h, o pauzė – 2 h, sąlygojo 29 % didesnį BSM dalies SM kiekio atžvilgiu sumažėjimą pūdymo proceso metu bei 8,2 % didesnę metano koncentraciją biodujose.; The anaerobic sludge digestion is widely used method for sludge stabilization. During digestion processes 50% amount of sludge can be reduced. As a by-product of the stabilization process biogas is produced, unpleasant sludge odour and pathogenic organisms are removed. Anaerobic digestion is affected by environmental factors and technological parameters, like loading regime. The comparable analysis of four Lithuanian WWTP is performed according to quality of primary and excess sludge, proportional content of sludge mixture, as well as environmental and technological parameters. Comparing the indicators characterizing the sludge digestion process of selected WWTPs, it is determined that two time shorter sludge loading regime to the digestion process with 4 hours supply and 2 hours pause stipulated higher reduction of VS as fraction of DS by 29% and higher concentration of methane in biogas by 8.2%.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
</feed>
