<title>Evaluation of the expediency of the use hybrid ventilation in hospital nursing corp</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/157003" rel="alternate"/>
<author>
<name>Poteshkin, Mikhail</name>
</author>
<author>
<name>Motuzienė, Violeta</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/157003</id>
<updated>2025-03-24T10:19:47Z</updated>
<published>2020-01-01T00:00:00Z</published>
<summary type="text">Evaluation of the expediency of the use hybrid ventilation in hospital nursing corp
Poteshkin, Mikhail; Motuzienė, Violeta
In this article, one of the Lithuanian hospitals, which was renovated in 2010, will be analysed. This work will analyse indoor microclimate parameters in the wards with natural and mechanical ventilation. For analysing this hospital’s indoor climate, some measurements in the wards were made and all the parameters were analysed. Moreover, for improving indoor parameters, for this work, natural ventilation in summer periods was designed, making ventilation in hospital hybrid. Because of this action, the consumption of electricity is reduced. In the last part of this work, there will be some analyses of price and CO2 cuts.; Šiame straipsnyje aprašomi vienos iš renovuotų Lietuvos&#13;
ligoninių patalpų mikroklimato parametrų tyrimai palatose su&#13;
natūralia ir mechanine ventiliacija.&#13;
Tyrimo metu buvo apskaičiuoti ir išanalizuoti palatų&#13;
temperatūros ir CO2 koncentracijos rodikliai. Siekiant pagerinti&#13;
patalpų tyrimo rezultatus vasaros laikotarpiui buvo suprojektuota&#13;
natūrali ventiliacija, įdiegiant mišrią ventiliacijos sistemą.&#13;
Šito pasėkoje sumažėjo elektros energijos sąnaudos ir CO2&#13;
emisija.
</summary>
<dc:date>2020-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Mikroklimato parametrų ir oro kokybės rodiklių tyrimas asmens sveikatos priežiūros įstaigoje</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/157002" rel="alternate"/>
<author>
<name>Olechnovičius, Edmundas</name>
</author>
<author>
<name>Misevičiūtė, Violeta</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/157002</id>
<updated>2025-03-24T10:21:44Z</updated>
<published>2020-01-01T00:00:00Z</published>
<summary type="text">Mikroklimato parametrų ir oro kokybės rodiklių tyrimas asmens sveikatos priežiūros įstaigoje
Olechnovičius, Edmundas; Misevičiūtė, Violeta
Analizuojamos asmens sveikatos priežiūros įstaigose esamos su mikroklimato parametrais ir oro kokybe susijusios problemos, nagrinėjama informacija apie poliklinikos pacientų ir personalo šiluminio komforto pojūtį. Straipsnyje aprašomi mikroklimato parametrų ir oro kokybės rodiklių tyrimo rezultatai, matavimus atlikus asmens sveikatos priežiūros paslaugas teikiančioje įstaigoje. Šiluminio komforto ir oro kokybės užtikrinimo lygis analizuotas šiltuoju ir šaltuoju metų laikotarpiu, trijose skirtingos paskirties, modernizuotose ir nemodernizuotose patalpose. Minėtose patalpose atlikti matavimai, kurių metu fiksuotos oro temperatūros, santykinės drėgmės ir CO2 koncentracijos ore vertės. Atliekant tyrimą taikyta EN ISO 7730 tarptautiniame standarte pateikta metodika ir vertinant šiluminio komforto lygį buvo vykdyta poliklinikos pacientų ir personalo anketinė apklausa. Matavimo rezultatai parodė, kad šiltuoju metų laikotarpiu oro kokybės rodikliai tirtose patalpose atitiko higienos normose nustatytas ribas. Šaltuoju metų laikotarpiu nustatyta, kad visose patalpose darbo dienomis išmatuotos CO2 koncentracijos reikšmės viršijančios norminius reikalavimus. Be to, šaltuoju laikotarpiu visos patalpos ne-stipriai peršildomos ir nepakankamai vėdinamos, tačiau didesnė dalis apklaustųjų respondentų nurodė, kad komfortabiliau jaučiasi šiltesnėje modernizuotoje patalpoje.; The paper analyses the results of indoor climate parameters&#13;
and air quality indicators. Measurements have been performed at&#13;
a personal health care facility. The level of thermal comfort and&#13;
air quality assurance was analysed during the warm and cold&#13;
season, in three different, modernized and non-modernized&#13;
premises. Measurements have been performed in the aforementioned&#13;
premises, during which values of air temperature, relative&#13;
humidity and CO2 concentration in the air were recorded. The&#13;
methodology presented in EN ISO 7730 International Standard&#13;
has been applied to the study and a survey conducted. The results&#13;
of the measurements showed that during the warm season the air&#13;
quality indicators in the examined premises were within the&#13;
limits set by the hygiene norms. During the cold season,&#13;
measured values of CO2 concentrations were above the&#13;
regulatory requirements on all working days at all premises. In&#13;
addition, during the cold period, all rooms are mildly overheated&#13;
and insufficiently ventilated, but the majority of respondents said&#13;
that they feel more comfortable in a warmer modernized room.
</summary>
<dc:date>2020-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Orinio šilumos siurblio šilumokaičio užšalimo mažinimo ir valdymo būdai</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/157001" rel="alternate"/>
<author>
<name>Kropas, Tomas</name>
</author>
<author>
<name>Streckienė, Giedrė</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/157001</id>
<updated>2025-03-24T10:21:24Z</updated>
<published>2020-01-01T00:00:00Z</published>
<summary type="text">Orinio šilumos siurblio šilumokaičio užšalimo mažinimo ir valdymo būdai
Kropas, Tomas; Streckienė, Giedrė
Vis plačiau naudojant šilumos siurblius pastatų šildymui šaltuoju metų sezonu, išryškėja jų garintuvo šilumokaičio užšalimo problema. Šiame straipsnyje aptariamos pagrindinės užšalimo sukeliamos problemos, jų įtaka sistemos veikimui bei įrenginio efektyvumui – COP. Taip pat pateikiamos pagrindinės šerkšno ir ledo susidarymo mažinimo bei valdymo priemonės. Pastarosios išskiriamos į dvi grupes: aktyviąsias ir pasyviąsias. Aktyviosios priemonės daugiau susijusios su šilumos siurblio šilumokaičių paviršiaus apdirbimu, bet jų įtaka, palyginus su aktyviosiomis priemonėmis, yra mažesnė. Tarp aktyviųjų priemonių, kurių įtaka didesnė, bene, populiariausios yra reversinis šilumos siurblio ciklas ir karštų garų apėjimo linija (ang. hot gas bypass). Kitos apžvelgiamos priemonės reikalauja papildomos įrangos, dėl kurių išauga sistemos kaštai bei sudėtingumas. Vis dėlto, geriausią rezultatą galima pasiekti derinant aktyviąsias ir pasyviąsias priemones.; With the increasing use of heat pumps for heating in&#13;
buildings during the cold season, the importance of freezing&#13;
problem of evaporator heat exchanger is growing. This article&#13;
discusses the main problems caused by freezing – frost formation,&#13;
their impact on the operation and efficiency of the system&#13;
– COP. The main frost and ice reduction and control&#13;
measures are also presented. These are divided into two groups:&#13;
active and passive. Active measures are more related to the&#13;
surface treatment of heat pump heat exchangers but their impact&#13;
is smaller compared to active measures. Among the active&#13;
measures with a greater impact, probably the most popular are&#13;
the reversible heat pump cycle and the hot gas bypass. Other&#13;
measures require additional equipment, which increases the cost&#13;
and complexity of the system. However, the best result can be&#13;
achieved by combining active and passive measures.
</summary>
<dc:date>2020-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>A+ energinės klasės gyvenamojo pastato energijos poreikių palyginimas skirtingomis klimato sąlygomis</title>
<link href="https://etalpykla.vilniustech.lt/handle/123456789/157000" rel="alternate"/>
<author>
<name>Grinevičiūtė, Monika</name>
</author>
<author>
<name>Valančius, Kęstutis</name>
</author>
<id>https://etalpykla.vilniustech.lt/handle/123456789/157000</id>
<updated>2025-03-24T10:20:34Z</updated>
<published>2020-01-01T00:00:00Z</published>
<summary type="text">A+ energinės klasės gyvenamojo pastato energijos poreikių palyginimas skirtingomis klimato sąlygomis
Grinevičiūtė, Monika; Valančius, Kęstutis
Šiame darbe nagrinėjamas A+ energinės klasės gyvenamojo pastato energijos poreikis skirtingose Europos klimato zonose. Siekiant išsiaiškinti klimatinių sąlygų daromą įtaką pastato energijos suvartojimui, gyvenamasis pastatas analizuojamas keturiais skirtingais variantais – naudojant Lietuvos, Suomijos, Austrijos bei Italijos klimatinius duomenis. Pastatas modeliuojamas „IDA Indoor Climate and Energy“ kompiuterinio modeliavimo programiniu paketu. Pastato modelis sukuriamas pagal tiriamose valstybėse galiojančius įstatymus energetiškai efektyviems pastatams. Darbo tikslas – išsiaiškinti pastato pirminės energijos poreikių ir klimatinių sąlygų priklausomybę. Spartėjant klimato kaitai bei kintant klimato sąlygoms, tokio pobūdžio analizė padės tinkamai įvertinti energines ir ekonomines sąnaudas.; The article analyses heating, and cooling demand of the&#13;
residential buildings constructed in Lithuania, Finland, Italy and&#13;
Austria. The “IDA Indoor Climate and Energy” software has&#13;
been applied for simulations of buildings energy demands. The&#13;
energy demand of A+ energy class building in Lithuania was&#13;
compared with the buildings’ needs constructed in other&#13;
analysed countries. The connection between demand and&#13;
climate zones was identified and overviewed. The paper&#13;
reviews the obtained results, perform analysis of various&#13;
simulations, and draws conclusions.