Show simple item record

dc.contributor.authorKropas, Tomas
dc.contributor.authorStreckienė, Giedrė
dc.contributor.authorBielskus, Juozas
dc.date.accessioned2023-09-18T16:09:23Z
dc.date.available2023-09-18T16:09:23Z
dc.date.issued2021
dc.identifier.issn1822-7554
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/111902
dc.description.abstractThe application of heat pumps for buildings heating systems in the cold or transitional season of the year is increasingly common not only in Lithuania but also in other European Union countries. Due to the growing popularity of air to air or air to water heat pumps in the building sector, the problem of evaporator heat exchanger freezing is also increasing in importance. As the outdoor temperature drops, the heat pump's efficiency – coefficient of performance for heating (COP) decreases. At high relative humidity there is also a risk of the evaporator heat exchanger to start freezing. This increases the energy consumption of the system, has a negative effect on heat exchange. Given the need for experimental and numerical research, the aim of this work is to analyse and present the characteristics of air source heat pump (ASHP) in the presence of the risk of freezing and to qualitatively assess the COP reduction due to frost formation. This paper investigates the operation of an ASHP in the cold season, observes the freezing of the evaporator as environmental conditions change. An experimental stand was constructed for this research; the necessary measuring devices and a camera were installed for visual observation of the experiment and assessment of frost formation. The experiments were carried out during the transitional - cold season of the year. It was found that frost formation on the evaporator started when the outdoor temperature was <3.5 °C and the relative humidity reached 88%. The defrost cycle took an average of 5 minutes. The impact of evaporator freezing on the operation and efficiency of the system - COP - has been assessed.eng
dc.format.extentp. 169-170
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.rightsLaisvai prieinamas internete
dc.source.urihttps://cyseni.com/wp-content/archives/proceedings/Proceedings_of_CYSENI_2021.pdf
dc.source.urihttps://cyseni.com/archive/
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:106567105/datastreams/MAIN/content
dc.titleExperimental investigation of frost on an air-source heat pump evaporator
dc.typeKonferencijos pranešimo santrauka / Conference presentation abstract
dcterms.references0
dc.type.pubtypeT2 - Konferencijos pranešimo tezės / Conference presentation abstract
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 006 - Energetika ir termoinžinerija / Energy and thermoengineering
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.studydirectionE13 - Energijos inžinerija / Energy engineering
dc.subject.vgtuprioritizedfieldsAE0303 - Pastatų energetika / Building energetics
dc.subject.ltspecializationsL102 - Energetika ir tvari aplinka / Energy and a sustainable environment
dc.subject.enair source heat pump (ASHP)
dc.subject.encoefficient of performance (COP)
dc.subject.enheating
dc.subject.encold season
dc.subject.enfreezing, defrost cycle
dcterms.sourcetitleCYSENI 2021: 17th international conference of young scientists on energy and natural sciences issues, 24-28 May 2021, Kaunas, Lithuania
dc.publisher.nameLithuanian Energy Institute
dc.publisher.cityKaunas
dc.identifier.elaba106567105


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record