Show simple item record

dc.contributor.authorZavadskas, Edmundas Kazimieras
dc.contributor.authorKalibatas, Darius
dc.contributor.authorKalibatienė, Diana
dc.date.accessioned2023-09-18T16:27:15Z
dc.date.available2023-09-18T16:27:15Z
dc.date.issued2016
dc.identifier.issn1644-9665
dc.identifier.other(BIS)VGT02-000031060
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/114113
dc.description.abstractThe majority of present-day dwelling houses were constructed in the previous century, when energy efficiency was not as important as now. Therefore, there is a necessity to assess existing dwelling houses and refurbish them to satisfy energy efficient requirement and humans’ needs. To cover the first part, authors of this paper continue their discussion on optimal leaving place started previously. In this paper based on concepts “passive house” and “active house”, standards of European Union (EU) and Lithuania, the concept “optimal environment” is refined and defined. According to the presented concept of optimal environment, the MADM-opt method, which is based on the concept of optimal alternative, is refined in the paper also. It is applied for the WASPAS method to assess an indoor environment of six apartments in similar brick houses. The results show that MADM-opt can be used for the assessment of alternatives and their evaluation according to the optimal alternative. Moreover, it allows determining deviation of the assessed alternatives from the optimal alternative.eng
dc.formatPDF
dc.format.extentp. 76-85
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScienceDirect
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyAcademic Search Complete
dc.source.urihttp://dx.doi.org/10.1016/j.acme.2015.10.002
dc.subjectAE03 - Pastatų aprūpinimas energija, jos vartojimo būdai, sistemos ir procesai / Building of energy supply, it’s application methods, systems and processes
dc.titleA multi-attribute assessment using WASPAS for choosing an optimal indoor environment
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references46
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.contributor.facultyFundamentinių mokslų fakultetas / Faculty of Fundamental Sciences
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.researchfieldT 007 - Informatikos inžinerija / Informatics engineering
dc.subject.ltspecializationsL102 - Energetika ir tvari aplinka / Energy and a sustainable environment
dc.subject.enMulti-attribute assessment
dc.subject.enIndoor environment
dc.subject.enWASPAS
dc.subject.enPassive house
dc.subject.enActive house
dcterms.sourcetitleArchives of civil and mechanical engineering
dc.description.issueiss. 1
dc.description.volumeVol. 16
dc.publisher.nameElsevier
dc.publisher.cityWroclaw
dc.identifier.doi000367202100008
dc.identifier.doi10.1016/j.acme.2015.10.002
dc.identifier.elaba15107971


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record