Show simple item record

dc.contributor.authorNovickij, Vitalij
dc.contributor.authorGirkontaitė, Irutė
dc.contributor.authorGrainys, Audrius
dc.contributor.authorZinkevičienė, Auksė
dc.contributor.authorLastauskienė, Eglė
dc.contributor.authorŠvedienė, Jurgita
dc.contributor.authorPaškevičius, Algimantas
dc.contributor.authorMarkovskaja, Svetlana
dc.contributor.authorNovickij, Jurij
dc.date.accessioned2023-09-18T16:46:54Z
dc.date.available2023-09-18T16:46:54Z
dc.date.issued2016
dc.identifier.issn1335-8871
dc.identifier.other(BIS)VGT02-000033036
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/116625
dc.description.abstractElectroporation is an electric field induced phenomenon occurring when the permeability of the cell membrane is increased due to the excess of critical transmembrane potential. Fluorescent dye assays are frequently used for evaluation of the permeabilization rate, however, the protocols vary, which negatively affects the repeatability of the results. In this work we have designed experiments to investigate the protocols and threshold concentrations of the Propidium Iodide (PI) and YO -PRO -1 (YP) fluorescent dyes for evaluation of mammalian cell permeabilization induced by electroporation. The Sp2/0 mouse myeloma cells were used and the bursts of 100 μs x 8 electrical pulses of 0.8 –2 kV/cm were applied. It has been shown that the dye concentration has an influence on the detectable permeabilization, and the concentrations below 30 μM for PI and 1 μM for YP should be avoided for measurement of electro - permeabilization efficacy due to unreliable fluorescence signals. Further, based on the experimental data, the permeabilization curve for the S p2/0 myeloma cells in the 0.8 –2 kV/cm range has been presented.eng
dc.formatPDF
dc.format.extentp. 300-304
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyDOAJ
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScopus
dc.source.urihttps://doi.org/10.1515/msr-2016-0038
dc.subjectMC02 - Elektros ir elektroniniai įrenginiai bei sistemos / Electrical and electronic devices and systems
dc.titleMeasurement of transient permeability of Sp2/0 myeloma cells: flow cytometric study
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references28
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionValstybinis mokslinių tyrimų institutas Inovatyvios medicinos centras
dc.contributor.institutionVilniaus universitetas
dc.contributor.institutionGamtos tyrimų centras
dc.contributor.facultyElektronikos fakultetas / Faculty of Electronics
dc.subject.researchfieldN 010 - Biologija / Biology
dc.subject.researchfieldN 011 - Biofizika / Biophysics
dc.subject.researchfieldT 001 - Elektros ir elektronikos inžinerija / Electrical and electronic engineering
dc.subject.ltspecializationsL105 - Sveikatos technologijos ir biotechnologijos / Health technologies and biotechnologies
dc.subject.enElectroporation
dc.subject.enBD FACS Calibur
dc.subject.enAmnis FlowSight
dc.subject.enSp2/0 myeloma cells
dcterms.sourcetitleMeasurement science review
dc.description.issueno. 6
dc.description.volumevol. 16
dc.publisher.nameDe Gruyter
dc.publisher.cityWarsaw
dc.identifier.doi000393110600004
dc.identifier.doi2-s2.0-85008194219
dc.identifier.doi10.1515/msr-2016-0038
dc.identifier.elaba19811073


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record