| dc.contributor.author | Baltrėnas, Pranas | |
| dc.contributor.author | Baltrėnaitė-Gedienė, Edita | |
| dc.date.accessioned | 2023-09-18T17:13:32Z | |
| dc.date.available | 2023-09-18T17:13:32Z | |
| dc.date.issued | 2018 | |
| dc.identifier.issn | 1735-6865 | |
| dc.identifier.uri | https://etalpykla.vilniustech.lt/handle/123456789/120923 | |
| dc.description.abstract | The analysis of the two-level multi-channel cyclone operation requires the investigation of the treated air flow movement. The two-level multi-channel cyclone was designed for separating solid particles from the air flow and constructed at the Institute of the Enviro nmental Protection of Vilnius Gediminas Technical University. The study was aimed at determining airflow distribution in a two-level six-channel cyclone and measur ing air treatme nt efficiency. To determine the velocity of airflow in the channels, a multi-functional measuring instrument Testo-400 and the dynamic Pitot tube were used. The concentration of particles in the air inlet and outlet ducts was determined by the weight method. The obtained results showed that the same air volumes on both cyclone levels are equal and the velocity of the airflow was uniformly distributed in the channels. The maximum airflow velocity was recorded in the first channel. The mea n airflow velocity in the channels did not differ significantly. | eng |
| dc.format | PDF | |
| dc.format.extent | p. 459-469 | |
| dc.format.medium | tekstas / txt | |
| dc.language.iso | eng | |
| dc.relation.isreferencedby | Science Citation Index Expanded (Web of Science) | |
| dc.relation.isreferencedby | Zoological Record | |
| dc.relation.isreferencedby | SpringerLink | |
| dc.relation.isreferencedby | Scopus | |
| dc.relation.isreferencedby | Astrophysics Data Systems | |
| dc.relation.isreferencedby | GEOBASE | |
| dc.source.uri | https://doi.org/10.1007/s41742-018-0104-0 | |
| dc.subject | AE01 - Aplinkos sistemos ir aplinkos apsaugos technologijos / Environmental systems and environment protection technologies | |
| dc.title | The experimental study on the principal aerodynamic characteristics and their influence on the efficiency in a cylindrical two-level six-channel cyclone to remove dissimilar types of particles | |
| dc.type | Straipsnis Web of Science DB / Article in Web of Science DB | |
| dcterms.references | 18 | |
| dc.type.pubtype | S1 - Straipsnis Web of Science DB / Web of Science DB article | |
| dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
| dc.contributor.faculty | Aplinkos inžinerijos fakultetas / Faculty of Environmental Engineering | |
| dc.subject.researchfield | T 004 - Aplinkos inžinerija / Environmental engineering | |
| dc.subject.ltspecializations | L102 - Energetika ir tvari aplinka / Energy and a sustainable environment | |
| dc.subject.en | aerodynamic resistance | |
| dc.subject.en | multi-channel cyclone | |
| dc.subject.en | air velocity | |
| dc.subject.en | solid particles | |
| dc.subject.en | air treatment | |
| dcterms.sourcetitle | International journal of environmental research | |
| dc.description.issue | iss. 4 | |
| dc.description.volume | vol. 12 | |
| dc.publisher.name | Springer | |
| dc.publisher.city | Cham | |
| dc.identifier.doi | 000437413700006 | |
| dc.identifier.doi | 2-s2.0-85049576323 | |
| dc.identifier.doi | 10.1007/s41742-018-0104-0 | |
| dc.identifier.elaba | 28169621 | |