Rodyti trumpą aprašą

dc.contributor.authorDaunoravičienė, Kristina
dc.contributor.authorŽižienė, Jurgita
dc.contributor.authorGriškevičius, Julius
dc.contributor.authorPauk, Jolanta
dc.contributor.authorOvčinikova, Agnė
dc.contributor.authorKizlaitienė, Rasa
dc.contributor.authorKaubrys, Gintaras Ferdinandas
dc.date.accessioned2023-09-18T17:13:51Z
dc.date.available2023-09-18T17:13:51Z
dc.date.issued2018
dc.identifier.issn0928-7329
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/120989
dc.description.abstractBACKGROUND: Upper extremity (UE) motor function deficits are commonly noted in multiple sclerosis (MS) patients and assessing it is challenging because of the lack of consensus regarding its definition. Instrumented biomechanical analysis of upper extremity movements can quantify coordination with different spatiotemporal measures and facilitate disability rating in MS patients. OBJECTIVE: To identify objective quantitative parameters for more accurate evaluation of UE disability and relate it to existing clinical scores. METHODS: Thirty-four MS patients and 24 healthy controls (CG) performed a finger-to-nose test as fast as possible and, in addition, clinical evaluation kinematic parameters of UE were measured by using inertial sensors. RESULTS: Generally, a higher disability score was associated with an increase of several temporal parameters, like slower task performance. The time taken to touch their nose was longer when the task was fulfilled with eyes closed. Time to peak angular velocity significantly changed in MS patients (EDSS > 5.0). The inter-joint coordination significantly decreases in MS patients (EDSS 3.0–5.5). Spatial parameters indicated that maximal ROM changes were in elbow flexion. CONCLUSIONS: Our findings have revealed that spatiotemporal parameters are related to the UE motor function and MS disability level. Moreover, they facilitate clinical rating by supporting clinical decisions with quantitative data.eng
dc.formatPDF
dc.format.extentp. 647-653
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyConference Proceedings Citation Index - Science (Web of Science)
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyPubMed
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyMEDLINE
dc.relation.isreferencedbyEmbase
dc.relation.isreferencedbyHealth & Safety Science Abstracts
dc.relation.isreferencedbyAcademic Source Complete
dc.rightsNeprieinamas
dc.source.urihttps://content.iospress.com/download/technology-and-health-care/thc182511?id=technology-and-health-care%2Fthc182511
dc.subjectMC01 - Biomechatroninės sistemos / Biomechatronical systems
dc.titleQuantitative assessment of upper extremities motor function in multiple sclerosis
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.accessRights12th International Conference on BIOmechanics, Medical Diagnostics, LOcomotion and REhabilitation (BIOMDLORE), Bialystok, Poland, June 28-30, 2018
dcterms.references11
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionBialystok University of Technology
dc.contributor.institutionVilniaus universitetas
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.researchfieldM 001 - Medicina / Medicine
dc.subject.ltspecializationsL105 - Sveikatos technologijos ir biotechnologijos / Health technologies and biotechnologies
dc.subject.enMultiple sclerosis
dc.subject.enFinger-to-nose test
dc.subject.enEDSS
dc.subject.enQuantitative assessment
dcterms.sourcetitleTechnology and health care
dc.description.issueiss. S2
dc.description.volumevol. 26
dc.publisher.nameIOS Press
dc.publisher.cityAmsterdam
dc.identifier.doi000436078900013
dc.identifier.doi2-s2.0-85049537897
dc.identifier.doi10.3233/THC-182511
dc.identifier.elaba29646286


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą