dc.description.abstractElastic modulus of the furniture coatings is an important parameter, which indicates the curing state of the composite resin curable by the ultraviolet radiation. Non-contact way of elastic modulus measurement by the transverse acoustical waves, propagating perpendicular to the surface of a 10 μm thick polymer, is shown as a suitable principle of the curing state sensing during furniture production. Transverse waves were excited by the cone-shaped ultrasound transducer having its frequency band centered at 1 MHz and captured with a receive transducer within 10 to 30 mm distance away from the excitation point. This setup allows to measure the differences of the time of flight of the pulse of the transverse waves in respect of the curing state in a non-contact regime. Numerical simulation and experimental results have led to the function, which relates the time of flight with the elastic modulus of the polymer coating, which was identified to be less than 1.95 GPa for an insufficiently cured polymer up to a 2.25 GPa in the case when cured as specified by the manufacturer. These values were confirmed by the AFM force-separation curve measurement technique, used here as the reference measurement channel.eng
dc.formatPDF
dc.format.extentp. 6527-6532
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyINSPEC
dc.source.urihttps://ieeexplore.ieee.org/document/8395373/
dc.titleNon-contact sensing of elastic modulus of the UV cured furniture coatings by the transverse acoustical waves
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references13
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionKauno technologijos universitetas VšĮ Panevėžio mechatronikos centras
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionUAB "Factobotics", Vilnius
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.researchfieldT 001 - Elektros ir elektronikos inžinerija / Electrical and electronic engineering
dc.subject.vgtuprioritizedfieldsMC03 - Išmaniosios įterptinės sistemos / Smart embedded systems
dc.subject.ltspecializationsL104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies
dc.subject.enfurniture industry
dc.subject.enUV curing
dc.subject.enelastic modulus
dc.subject.enultrasonic transducers
dc.subject.enacoustic waves
dc.subject.enAFM
dcterms.sourcetitleIEEE sensors journal
dc.description.issueiss. 16
dc.description.volumevol. 18
dc.publisher.nameIEEE
dc.publisher.cityPiscataway, NJ
dc.identifier.doi2379-9153
dc.identifier.doi2-s2.0-85049128933
dc.identifier.doi000439966100007
dc.identifier.doi18912237
dc.identifier.doi10.1109/JSEN.2018.2850362
dc.identifier.elaba29734633


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record