Rodyti trumpą aprašą

dc.contributor.authorJakštas, Aurimas
dc.contributor.authorKaušinis, Saulius
dc.contributor.authorBarauskas, Rimantas
dc.contributor.authorKasparaitis, Albinas
dc.contributor.authorBarakauskas, A.
dc.date.accessioned2023-09-18T17:27:50Z
dc.date.available2023-09-18T17:27:50Z
dc.date.issued2011
dc.identifier.issn0263-2241
dc.identifier.other(BIS)KTU02-000046491
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/123445
dc.description.abstractThe article treats the issue of embedding the traceable length metrology directly into technological process by performing precise dynamic measurements of line scale in real industrial environment. It addresses the error-related problems specific to line scale calibration in dynamic mode of operation that are caused primarily by static and dynamic loads as well as geometrical deviations of the calibration system components. Introducing the dynamic regime of calibration leads to the dynamic calibration error originating due to vibration sources in the structure. This term should be considered and implicated in the measurement uncertainty budget. A new 3D finite element model has been developed in order to both investigate the influence of dynamical excitations of a long stroke comparator structure and evaluate possible influence of vibrations on geometrical dimensions of the line scale. The experiments have been conducted on the new interferometer-controlled comparator setup with a moving microscope in order to evaluate the performance of the precision scale calibration process.eng
dc.formatPDF
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyAcademic Search Premier
dc.relation.isreferencedbyCompendex
dc.relation.isreferencedbyINSPEC
dc.source.urihttp://dx.doi.org/10.1016/j.measurement.2011.02.004
dc.titleInvestigation of dynamics-induced errors of long line scale calibration systems
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references9
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionKauno technologijos universitetas
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionUAB "Precizika-Metrology"
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldT 010 - Matavimų inžinerija / Measurement engineering
dc.subject.endynamic line scale calibration
dc.subject.enFE modelling
dc.subject.en3D finite element model
dcterms.sourcetitleMeasurement
dc.description.issueiss. 5
dc.description.volumevol. 44
dc.publisher.nameElsevier
dc.publisher.cityOxford
dc.identifier.doiVGT02-000022625
dc.identifier.doi000290138700022
dc.identifier.doi2-s2.0-79953777563
dc.identifier.doi10.1016/j.measurement.2011.02.004
dc.identifier.elaba3169185


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą