dc.contributor.author | Jokūbaitis, Aidas | |
dc.contributor.author | Marčiukaitis, Jonas Gediminas | |
dc.contributor.author | Valivonis, Juozas | |
dc.contributor.author | Strauss, Alfred | |
dc.date.accessioned | 2023-09-18T17:29:46Z | |
dc.date.available | 2023-09-18T17:29:46Z | |
dc.date.issued | 2018 | |
dc.identifier.issn | 1464-4177 | |
dc.identifier.uri | https://etalpykla.vilniustech.lt/handle/123456789/123808 | |
dc.description.abstract | This paper presents the results of an experimental research investigating the influence of static and cyclic loading and frost impact on the bond between concrete and 6.2 mm three‐wire‐strand. From the pullout tests, it was determined that a cyclic load did not negatively influence the bond strength of three‐wire strand. On the contrary, the influence of cyclic loading after 200 freezing and thawing cycles resulted in a significant decrease of bond strength of three‐wire strand. Additionally, the new parameters for bond stress–slip relationship suggested in Model Code 2010 are proposed for the 6.2 mm three‐wire strand cast with concrete having compressive strength of 82.6 MPa with standard deviation of 6.65 MPa. The results of dynamic coefficient b for 6.2 mm three‐wire strand used in relationship between a slip of reinforcement and a number of loading cycles under unidirectional cyclic loading suggested in Model Code 2010 are analyzed. | eng |
dc.format | PDF | |
dc.format.extent | p. 1363-1375 | |
dc.format.medium | tekstas / txt | |
dc.language.iso | eng | |
dc.relation.isreferencedby | INSPEC | |
dc.relation.isreferencedby | Compendex | |
dc.relation.isreferencedby | Science Citation Index Expanded (Web of Science) | |
dc.relation.isreferencedby | Scopus | |
dc.source.uri | https://doi.org/10.1002/suco.201700245 | |
dc.title | Influence of cyclic loading and frost on the behavior of bond of three‐wire strand | |
dc.type | Straipsnis Web of Science DB / Article in Web of Science DB | |
dcterms.references | 48 | |
dc.type.pubtype | S1 - Straipsnis Web of Science DB / Web of Science DB article | |
dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
dc.contributor.institution | University of Natural Resources and Life Sciences | |
dc.contributor.faculty | Statybos fakultetas / Faculty of Civil Engineering | |
dc.subject.researchfield | T 002 - Statybos inžinerija / Construction and engineering | |
dc.subject.vgtuprioritizedfields | SD0101 - Pažangios statinių konstrukcijos / Smart building structures | |
dc.subject.ltspecializations | L104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies | |
dc.subject.en | bond | |
dc.subject.en | cyclic load | |
dc.subject.en | frost | |
dc.subject.en | pullout test | |
dc.subject.en | strand | |
dcterms.sourcetitle | Structural concrete | |
dc.description.issue | iss. 5 | |
dc.description.volume | vol. 19 | |
dc.publisher.name | John Wiley & Sons | |
dc.publisher.city | Berlin | |
dc.identifier.doi | 000447557800012 | |
dc.identifier.doi | 2-s2.0-85053068765 | |
dc.identifier.doi | 10.1002/suco.201700245 | |
dc.identifier.elaba | 31933564 | |