dc.description.abstractVarious protective barriers are used in practice to protect reinforced concrete structures in severely aggressive environments. In this paper, we consider a multi-component corrosion protection system (CPS), taking into account the performance of protective surface barrier, concrete cover and steel reinforcement, which is modelled as a three-unit of non-identical components cold standby system. The system is non-maintained. This is the case when the system is not easily accessible for repair, repair; is time-consuming and costly. In this system it is assumed that degradation rates of all components are exponential and different. Under these assumptions, using the Markovian degradation process, some important reliability indices such as the system reliability and mean time to failure are defined. In addition, we present simulation results to substantiate the analytical model and to demonstrate the sensitivity analysis to estimate protection system reliability.eng
dc.description.abstractIvairios apsauginės dangos naudojamos gelžbetoninėms konstrukcijoms stipriai agresyvioje aplinkoje apsaugoti. Straipsnyje nagrinėjama daugiasluoksnė antikorozinė apsauga, susidedanti iš apsauginio barjero, betoninio apsauginio sluoksnio ir plieninės armatūros. Sistema modeliuojama kaip trijų nevienodų komponentų šaltai rezervinė sistema. Ši sistema yra neremontuojama. Tai atvejai, kai sistema sunkiai pasiekiama, remontas ilgai trunka arba brangus. Tariama, kad sistemos visų komponentų irimo intensyvumas yra eksponentinis ir skirtingas. Remiantis šiomis prielaidomis, naudojant Markovo suirties (atnaujinimo) teorija, kai kurie svarbūs patikimumo rodikliai, tokie kaip sistemos patikimumas ir vidutinis laikas iki suirties, gali būti nustatyti. Skaitinis pavyzdys iliustruoja analitinio modelio taikymą ir jo jautrumą vertinant antikorozinės apsauginės sistemos patikimumą.lit
dc.formatPDF
dc.format.extentp. 387-394
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyAcademic Search Complete
dc.relation.isreferencedbyVINITI
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyCompendex
dc.relation.isreferencedbyICONDA
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.titleModelling of corrosion protection as standby system for coated reinforced concrete structures
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references27
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.ltAntikorozinė apsauga
dc.subject.ltNeremontuojama sistema
dc.subject.ltRezervinė sistema
dc.subject.ltMarkovo procesas
dc.subject.ltPatikimumas
dc.subject.ltLaikas iki suirties
dc.subject.enReinforced concrete
dc.subject.enAnti-corrosion protection
dc.subject.enNon-repairable system
dc.subject.enStandby system
dc.subject.enMarkovian process
dc.subject.enReliability
dc.subject.enTime to failure
dcterms.sourcetitleJournal of civil engineering and management: international research and achievements
dc.description.issueno 4
dc.description.volumeVol. 15
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.doi000272402900007
dc.identifier.doi2-s2.0-73349089641
dc.identifier.doi10.3846/1392-3730.2009.15.387-394
dc.identifier.elaba3887006


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą