dc.description.abstract | Life cycle analysis is a widespread method in most countries. Its principle is to evaluate direct and indirect influences of searching object on environment during its all life cycle. Life cycle model calculations of two existing district heating distribution networks were investigated in this case. Two variants of district heating network maintenance works were computed and compared: renovations using pipes assembled in channels and pre-insulated pipes technologies. Primary energy, heat losses, expenses for maintenance works and heat losses were calculated. The most suitable periodicities of maintenance works and character of the networks depreciation using those periodicities were determined. | eng |
dc.description.abstract | Gyvavimo ciklo analizė - daugelyje šalių plačiai taikomas metodas. Jo principas - nustatyti tiesioginę ir netiesioginę tiriamojo objekto įtaką aplinkai per visą jo gyvavimo ciklą. Buvo išnagrinėti dviejų veikiančių centralizuoto šilumos tiekimo tinklų gyvavimo ciklo modelio skaičiavimai. Apskaičiuoti ir palyginti du centralizuoto šilumos tiekimo tinklų remonto darbų variantai: renovacijos pagal kanalinę ir bekanalę vamzdžių klojimo technologijas. Atlikti pirminės energijos, šilumos nuostolių, išlaidų remontams ir šilumos nuostoliams skaičiavimai. Nustatyti tinkamiausi remonto darbų atlikimo periodiškumai ir juos atitinkančios tinklų nusidėvėjimo tendencijos. | lit |
dc.format | PDF | |
dc.format.extent | p. 104-109 | |
dc.format.medium | tekstas / txt | |
dc.language.iso | eng | |
dc.relation.isreferencedby | VINITI | |
dc.relation.isreferencedby | METADEX | |
dc.source.uri | http://www.tandfonline.com/doi/pdf/10.1080/13923730.2003.10531312 | |
dc.title | Estimation of existing district heating distribution network from the standpoint of life cycle analysis | |
dc.title.alternative | Veikiančių šilumos tinklų vertinimas gyvavimo ciklo požiūriu | |
dc.type | Straipsnis kitoje DB / Article in other DB | |
dcterms.references | 11 | |
dc.type.pubtype | S3 - Straipsnis kitoje DB / Article in other DB | |
dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
dc.contributor.faculty | Aplinkos inžinerijos fakultetas / Faculty of Environmental Engineering | |
dc.subject.researchfield | T 006 - Energetika ir termoinžinerija / Energy and thermoengineering | |
dc.subject.lt | Centralizuoto šilumos tiekimo tinklas | |
dc.subject.lt | Gyvavimo ciklo analizė | |
dc.subject.lt | Sisteminė analizė | |
dc.subject.lt | Gyvavimo laikas | |
dc.subject.lt | Nusidėvėjimas | |
dc.subject.lt | Energijos taupymas | |
dc.subject.lt | Remonto darbų planavimas | |
dc.subject.en | District heating distribution network | |
dc.subject.en | Life cycle analysis | |
dc.subject.en | System analysis | |
dc.subject.en | Life span | |
dc.subject.en | Depreciation | |
dc.subject.en | Energy saving | |
dc.subject.en | Planning of maintenance works | |
dcterms.sourcetitle | Journal of civil engineering and management | |
dc.description.issue | no. 2 | |
dc.description.volume | Vol. 9 | |
dc.publisher.name | Technika | |
dc.publisher.city | Vilnius | |
dc.identifier.doi | 10.1080/13923730.2003.10531312 | |
dc.identifier.elaba | 3627879 | |