Show simple item record

dc.contributor.authorŠerevičienė, Vaida
dc.contributor.authorPaliulis, Dainius
dc.date.accessioned2023-09-18T19:00:45Z
dc.date.available2023-09-18T19:00:45Z
dc.date.issued2012
dc.identifier.issn2231-606X
dc.identifier.other(BIS)VGT02-000024456
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/134538
dc.description.abstractPassive diffusive samplers provide an excellent opportunity to perform indicative measurements or establish a dense network of measuring sites. This paper describe and present the results of experiments in exposure chamber to determine the effects of different ambient air temperature (T) and relatively humidity (RH) on the performances of passive diffusive samplers for measuring nitrogen dioxide (NO2) in the outdoor environment. In experimental studies were used passive diffusive samplers with stainless steel grids and impregnating solution of 10% (v/v) triethanolamine (TEA) with water. During these researches in laboratory chamber passive samplers was exposed at various conditions: temperature from 10°C to 40°C and relatively humidity from 30% to 80%. During these variations in conditions NO2 concentration was constant, approximately 40 μg/m3. Influence of temperature and relative humidity are weak on passive sampler performance when ambient temperature is 20°C and relatively humidity 60%. Changing environmental conditions (T > 30 °C and RH > 75 %) indicates accuracy of passive samplers 10–35% when compared to co-located continuous NOx analyzer.eng
dc.format.extentp. 89-92
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyChemical abstracts
dc.relation.isreferencedbyEbsco (nenaudotinas)
dc.relation.isreferencedbyCAB Abstracts
dc.source.urihttp://www.isca.in/rjcs/Archives/vol2/i5/15.ISCA-RJCS-2012-057_Done.pdf
dc.titleInfluence of temperature and relative humidity on the performance of nitrogen dioxide diffusive sampler
dc.typeStraipsnis kitoje DB / Article in other DB
dcterms.references20
dc.type.pubtypeS3 - Straipsnis kitoje DB / Article in other DB
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 004 - Aplinkos inžinerija / Environmental engineering
dc.subject.enNitrogen dioxide
dc.subject.enDiffusive sampling
dc.subject.enAir monitoring
dc.subject.enTemperature
dc.subject.enRelatively humidity
dc.subject.enLaboratory chamber
dcterms.sourcetitleResearch journal of chemical sciences
dc.description.issueiss. 5
dc.description.volumeVol. 2
dc.publisher.nameIndian Academy of Sciences
dc.publisher.cityBangalore
dc.identifier.elaba3979237