Show simple item record

dc.contributor.authorKaklauskas, Artūras
dc.contributor.authorZavadskas, Edmundas Kazimieras
dc.contributor.authorRaslanas, Saulius
dc.contributor.authorGinevičius, Romualdas
dc.contributor.authorKomka, Arūnas
dc.contributor.authorMalinauskas, Pranas
dc.date.accessioned2023-09-18T19:33:26Z
dc.date.available2023-09-18T19:33:26Z
dc.date.issued2006
dc.identifier.issn0378-7788
dc.identifier.other(BIS)VGT02-000012421
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/140691
dc.description.abstractCalculations of building retrofit effectiveness have shown that the replacement of original windows with new ones is not as effective in terms of heat energy saving as are the insulation of a roof, walls and other improvements because the investments are large and take a long time to be repaid. However, in addition to energy saving, window replacement improves the indoor climate of the building, its interior and architectural appearance as well as its market value. The sequence of building operations determines when the replacement of windows should be done. When financial resources are limited, managers of public buildings often begin the renovation of a building's envelope with the replacement of windows. The client faces some problems in choosing among the great variety of windows to satisfy his/her needs, especially with respect to the cost-quality relationship. The method of multiple criteria complex proportional assessment (COPRAS) developed by the authors aims at solving the above-mentioned problems. The solutions based on multicriteria analysis allow for a more rational and realistic assessment of customer's needs as well as cutting down window renewal costs. In this paper, practical example (key-case) of selecting a contractor for the replacement of windows in the main building of Vilnius Gediminas Technical University (VGTU) is presented as a part of its retrofit multivariant design.eng
dc.formatPDF
dc.format.extentp. 454-462
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyCompendex
dc.relation.isreferencedbyScienceDirect
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.titleSelection of low-e windows in retrofit of public buildings by applying multiple criteria method COPRAS: A Lithuanian case
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references22
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.contributor.facultyVerslo vadybos fakultetas / Faculty of Business Management
dc.subject.researchfieldS 003 - Vadyba / Management
dc.subject.researchfieldS 004 - Ekonomika / Economics
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.enPublic building
dc.subject.enRetrofit
dc.subject.enCOPRAS
dcterms.sourcetitleEnergy and buildings
dc.description.issueiss. 5
dc.description.volumeVol. 38
dc.publisher.nameElsevier
dc.publisher.cityLausanne
dc.identifier.doi10.1016/j.enbuild.2005.08.005
dc.identifier.elaba3737557