Rodyti trumpą aprašą

dc.contributor.authorPilkytė, Laima
dc.contributor.authorButkus, Donatas
dc.contributor.authorMorkūnas, Gendrutis
dc.date.accessioned2023-09-18T19:48:00Z
dc.date.available2023-09-18T19:48:00Z
dc.date.issued2006
dc.identifier.issn0144-8420
dc.identifier.other(BIS)VGT02-000014419
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/143416
dc.description.abstractThe aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995–2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y–1. The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials.eng
dc.formatPDF
dc.format.extentp. 140-147
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.source.urihttps://academic.oup.com/rpd/article/121/2/140/1598075
dc.titleAssessment of external dose indoors in Lithuania
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references0
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas Radiacinės saugos centras
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 004 - Aplinkos inžinerija / Environmental engineering
dcterms.sourcetitleRadiation protection dosimetry
dc.description.issueno. 2
dc.description.volumeVol. 12
dc.publisher.nameOxford University Press
dc.publisher.cityOxford
dc.identifier.doi000242717700009
dc.identifier.doi10.1093/rpd/nci370
dc.identifier.elaba3776233


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą