Rodyti trumpą aprašą

dc.contributor.authorAviža, Donatas
dc.contributor.authorTurskis, Zenonas
dc.date.accessioned2023-09-18T20:05:27Z
dc.date.available2023-09-18T20:05:27Z
dc.date.issued2014
dc.identifier.issn1392-3730
dc.identifier.other(BIS)VGT02-000029248
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/146691
dc.description.abstractThe article provides the correlation analysis between the thickness of a thermo-insulation layer of the typical floor-on-soil sample and its simple payback time in a traditional new construction single-apartment residential and net-zero energy building. The calculations were carried out on the energy efficiency class of the building and the geographic area of the construction. On the basis of the results, a simple payback time was calculated. The main aim – thermal transmittance coefficients of soil touching partitions must satisfy the normative value of technical construction regulation and European standards. The research object of the study is relationships between the thickness of a thermoinsulation layer of the typical floor-on-soil sample and its simple payback time. Lithuania was chosen as the geographic area of the research. Calculations were carried out for seven towns: Vilnius, Kaunas, Klaipeda, Siauliai, Panevezys, Utena, and Dukstas. The test result – developed correlation functions. Correlation analysis results are important not only for designers making decisions during the pre-design stage, but also for energy consumption auditors and experts.eng
dc.formatPDF
dc.format.extentp. 760-766
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyAcademic Search Complete
dc.relation.isreferencedbyICONDA
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.source.urihttps://doi.org/10.3846/13923730.2014.937356
dc.subjectSD04 - Tvarus statinių gyvavimo ciklas / Sustainable lifecycle of the buildings
dc.titleAn empirical analysis of correlation between the thickness of a thermal insulation layer of the floor and the payback period
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references14
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas Kauno technologijos universitetas
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.contributor.facultyPersonalo direkcija / Human Resources Office
dc.contributor.departmentStatybos technologijos ir vadybos katedra / Department of Construction Technology and Management
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.ltspecializationsL102 - Energetika ir tvari aplinka / Energy and a sustainable environment
dc.subject.enresidential building
dc.subject.enthermo-insulation thicknesses
dc.subject.enpayback period
dc.subject.enenergy performance
dc.subject.encorrelation analysis
dc.subject.engeographic area
dcterms.sourcetitleJournal of civil engineering and management
dc.description.issueno. 5
dc.description.volumevol. 20
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.doi000343302900014
dc.identifier.doi2-s2.0-84908151599
dc.identifier.doi10.3846/13923730.2014.937356
dc.identifier.elaba4097833


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą