dc.description.abstract | Laboratory experiments were conducted to investigate the fate of the antimicrobial agent triclosan (TCS) in a conventional septic tank. The main mechanism of TCS removal from wastewater was identified to be rapid TCS sorption to suspended particles followed by settling of these particles to the bottom of the septic tank. Sorption to particles was completed within minutes while the settling took several days. Therefore, in a septic tank the removal of TCS from wastewater is mainly determined by the removal of suspended particles by sedimentation. Over 5 days of hydraulic residence time the initial dissolved TCS concentration of 100 μg L−1 was reduced by 87 ± 8%. During the first 24 hours, 66–86% of all removed TCS was retained, whereas during the remainder of the experiment a slight but steady decrease in TCS concentration was observed. This was most likely caused by TCS diffusion and its subsequent sorption onto the septic sludge. | eng |
dc.format | PDF | |
dc.format.extent | p. 586-592 | |
dc.format.medium | tekstas / txt | |
dc.language.iso | eng | |
dc.relation.isreferencedby | MEDLINE | |
dc.relation.isreferencedby | Science Citation Index Expanded (Web of Science) | |
dc.subject | AE01 - Aplinkos sistemos ir aplinkos apsaugos technologijos / Environmental systems and environment protection technologies | |
dc.title | Retainment of the antimicrobial agent triclosan in a septic tank | |
dc.type | Straipsnis Web of Science DB / Article in Web of Science DB | |
dcterms.references | 30 | |
dc.type.pubtype | S1 - Straipsnis Web of Science DB / Web of Science DB article | |
dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
dc.contributor.institution | Aalborg University | |
dc.contributor.faculty | Aplinkos inžinerijos fakultetas / Faculty of Environmental Engineering | |
dc.subject.researchfield | T 004 - Aplinkos inžinerija / Environmental engineering | |
dc.subject.ltspecializations | L102 - Energetika ir tvari aplinka / Energy and a sustainable environment | |
dc.subject.en | Anaerobic conditions | |
dc.subject.en | Septic tank | |
dc.subject.en | Sorption | |
dc.subject.en | Triclosan | |
dc.subject.en | Wastewater | |
dcterms.sourcetitle | Water science and technology | |
dc.description.issue | no. 4 | |
dc.description.volume | Vol. 70 | |
dc.publisher.name | IWA Publishing | |
dc.publisher.city | London | |
dc.identifier.doi | 10.2166/wst.2014.271 | |
dc.identifier.elaba | 4093163 | |