Rodyti trumpą aprašą

dc.contributor.authorŽurauskas, Edvardas
dc.contributor.authorUšinskienė, Jurgita
dc.contributor.authorGaigalaitė, Virginija
dc.contributor.authorBlanc, Raphael
dc.contributor.authorUšinskas, Andrius
dc.contributor.authorLaurinavičius, Arvydas
dc.date.accessioned2023-09-18T20:28:33Z
dc.date.available2023-09-18T20:28:33Z
dc.date.issued2007
dc.identifier.issn1010-660X
dc.identifier.other(BIS)VUB02-000028853
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/150104
dc.description.abstractVaškas ir jo pagrindo masės lengvai formuojamos gaminant kraujagyslių modelius rankomis, tačiau netinka anatominių arterijų preparatų užpildymui.lit
dc.description.abstractObjective. To delineate technical aspects of vascular models with intracranial aneurysm in vitro production, suitable for angiographic imaging. Material and methods. Wax (K2 exact, S-U-CERAMO-CAPS-WAX), Girtl’s mass, gelatin, and silicone (Silicone 10015 Den Braven, Elastosil 7683/25, Elite Double 32 Shore-A, Rema-Sil) were used for model production. Construction of models was based on T-shaped plastic tube connections and lost core techniques. Images of rotational angiography, glass tubes with aneurysm, and casts obtained in human specimen were used as samples of cerebral arteries. Results. Technical aspects of vascular models production were delineated in experience of eight silicone models produced. M1 was hand made with basilar tip aneurysm; M2 was obtained according to angiography images with internal carotid artery supraclinoid part bifurcation to anterior and middle cerebral artery aneurysm. BM1 and BM2 casts were made using glass tubes with lateral aneurysm, M3 – from T-shaped plastic tubes with lateral aneurysms. M4, M5, and M6 were formed using casts obtained in human specimen with basilar tip aneurysm. Conclusions. Silicone of two components is practical for casts of cerebral arteries in human specimen production. Gelatinous solution 50°C diluted 1:1 with water can be used for copies of arterial casts production. Wax materials are unsuitable for making casts in a human specimen.eng
dc.format.extentp. 562-567
dc.format.mediumtekstas / txt
dc.language.isolit
dc.relation.isreferencedbyMEDLINE
dc.relation.isreferencedbyDOAJ
dc.relation.isreferencedbyIndex Copernicus
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.rightsLaisvai prieinamas internete
dc.source.urihttp://medicina.lsmuni.lt/med/0707/0707-07l.pdf
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:6171156/datastreams/MAIN/content
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:6171156/datastreams/ATTACHMENT_6171171/content
dc.titleDirbtinių intrakranijinės aneurizmos modelių kūrimas angiografiniams tyrimams
dc.title.alternativeModels of intracranial aneurysms for angiographic imaging modalities. A technical note
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references12
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus universitetas
dc.contributor.institutionVilniaus universiteto ligoninės Santariškių klinikos
dc.contributor.institutionHenri Modor ligoninė
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyElektronikos fakultetas / Faculty of Electronics
dc.subject.researchfieldM 001 - Medicina / Medicine
dc.subject.researchfieldM 004 - Visuomenės sveikata / Public health
dc.subject.ltDirbtiniai kraujagyslių modeliai
dc.subject.ltIntrakranijinės aneurizmos
dc.subject.ltmetodologija
dc.subject.enBlood-vessels
dc.subject.enBiological models
dc.subject.enIntracranial aneurysms
dc.subject.enMethodology
dcterms.sourcetitleMedicina
dc.description.issuenr. 7
dc.description.volumet. 43
dc.identifier.doiVUB02-000028853
dc.identifier.doiELB01-000006657
dc.identifier.doiLT-eLABa-0001:J.04~2007~ISSN_1010-660X.V_43.N_7.PG_562-567
dc.identifier.doiVGT02-000016132
dc.identifier.elaba6171156


Šio įrašo failai

Thumbnail

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą