dc.contributor.author | Kurtinaitienė, Bogumila | |
dc.contributor.author | Vasiliauskienė, Dovilė | |
dc.contributor.author | Laurinavičius, Valdas Stanislovas | |
dc.contributor.author | Ramanavičienė, Almira | |
dc.contributor.author | Ramanavičius, Arūnas | |
dc.date.accessioned | 2023-09-18T20:28:42Z | |
dc.date.available | 2023-09-18T20:28:42Z | |
dc.date.issued | 2008 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.other | (BIS)LBT02-000034130 | |
dc.identifier.uri | https://etalpykla.vilniustech.lt/handle/123456789/150158 | |
dc.description.abstract | A new amperometric immunosensor for detection of antibodies against bovine leukemia protein (gp51) was designed. The detection of antibody-antigen complex formation was based on application of secondary antibodies labeled with horseradish peroxidase (HRP). Ferrocenecarboxylic acid (FCA) and N,N,N',N'-tetramethylbenzidine (TMB) were selected as suitable mediators for this immunosensor. Optimal conditions for amperometric detection were found. Sensitivity of created system was compared with the results of enzyme-linked immunosorbent assay (ELISA) and agar gel immunodiffusion (AGID) reaction, and was sufficient for detection of usual anti-gp51 antibody concentration present in the blood serum of BLV-infected cattle. | eng |
dc.format | PDF | |
dc.format.extent | p. 1547-1554 | |
dc.format.medium | tekstas / txt | |
dc.language.iso | eng | |
dc.relation.isreferencedby | Biological Abstracts | |
dc.relation.isreferencedby | Academic Search Premier | |
dc.relation.isreferencedby | MEDLINE | |
dc.relation.isreferencedby | Compendex | |
dc.relation.isreferencedby | Chemical abstracts | |
dc.relation.isreferencedby | ScienceDirect | |
dc.relation.isreferencedby | Science Citation Index Expanded (Web of Science) | |
dc.source.uri | https://doi.org/10.1016/j.bios.2008.01.014 | |
dc.title | Amperometric immunosensor for diagnosis of BLV infection | |
dc.type | Straipsnis Web of Science DB / Article in Web of Science DB | |
dcterms.references | 37 | |
dc.type.pubtype | S1 - Straipsnis Web of Science DB / Web of Science DB article | |
dc.contributor.institution | Biochemijos institutas Vilniaus Gedimino technikos universitetas | |
dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
dc.contributor.institution | Biochemijos institutas | |
dc.contributor.institution | Vilniaus universiteto Imunologijos institutas Vilniaus universitetas | |
dc.contributor.institution | Vilniaus universitetas | |
dc.contributor.faculty | Fundamentinių mokslų fakultetas / Faculty of Fundamental Sciences | |
dc.subject.researchfield | T 005 - Chemijos inžinerija / Chemical engineering | |
dc.subject.researchfield | N 003 - Chemija / Chemistry | |
dc.subject.en | Immunosensor | |
dc.subject.en | NanoBioTechnology | |
dc.subject.en | HRP | |
dc.subject.en | Redox mediator | |
dc.subject.en | Electrochemical sensor | |
dc.subject.en | TMB | |
dc.subject.en | FCA | |
dc.subject.en | BLV | |
dcterms.sourcetitle | Biosensors & bioelectronics | |
dc.description.issue | iss. 10 | |
dc.description.volume | vol. 23 | |
dc.identifier.doi | VGT02-000016592 | |
dc.identifier.doi | VUB02-000030612 | |
dc.identifier.doi | 10.1016/j.bios.2008.01.014 | |
dc.identifier.elaba | 5821675 | |