dc.description.abstractIn the present study, we aimed to determine the changes of indoor radon concentrations depending on various environmental parameters, such as the outdoor temperature, relative humidity, and air pressure, in university building premises of different applications and heights. The environmental parameters and indoor radon concentrations in four different premises were measured each working day over an eight-month period. The results showed that the indoor radon levels strongly depended on the outside temperature and outside relative humidity, whereas the weakest correlations were found between the indoor radon levels and indoor and outdoor air pressures. The obtained indoor radon concentration and environmental condition correlations were different for the different premises of the building. That is, in two premises where the ventilation effect through unintentional air leakage points prevailed in winter, positive correlations between the radon concentration and outside temperature were obtained, reaching the values of 0.94 and 0.92, respectively. In premises with better airtightness, negative correlations (R = −0.96 and R = −0.62) between the radon concentrations and outside temperature were obtained. The results revealed that high quality air isolation in premises could be an important factor for higher indoor radon levels during summer compared to winter.eng
dc.formatPDF
dc.format.extentp. 1-15
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyGenamics Journal Seek
dc.relation.isreferencedbyIDEAS
dc.relation.isreferencedbyRePec
dc.relation.isreferencedbyCABI Abstracts
dc.relation.isreferencedbyDOAJ
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbySocial Sciences Citation Index (Web of Science)
dc.rightsLaisvai prieinamas internete
dc.source.urihttps://doi.org/10.3390/su12156174
dc.source.urihttps://www.mdpi.com/2071-1050/12/15/6174
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:67613586/datastreams/MAIN/content
dc.titleSeasonal variation of indoor radon concentration levels in different premises of a university building
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.accessRightsThis article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
dcterms.licenseCreative Commons – Attribution – 4.0 International
dcterms.references41
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 004 - Aplinkos inžinerija / Environmental engineering
dc.subject.vgtuprioritizedfieldsAE05 - Antropogeninės aplinkos kaita / Change of anthropogenic environment
dc.subject.ltspecializationsL102 - Energetika ir tvari aplinka / Energy and a sustainable environment
dc.subject.enindoor radon concentration
dc.subject.enseasonal changes
dc.subject.enairtightness
dc.subject.enoutdoor temperature
dc.subject.enhumidity
dc.subject.enuniversity building
dcterms.sourcetitleSustainability
dc.description.issueiss. 15
dc.description.volumevo. 12
dc.publisher.nameMDPI
dc.publisher.cityBasel
dc.identifier.doi000559157600001
dc.identifier.doi10.3390/su12156174
dc.identifier.elaba67613586


Šio įrašo failai

Thumbnail
Thumbnail

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą