dc.description.abstractLoading of masonry with concentrated load is a sufficiently common case of loading which occurs due to structures of various purposes and sizes which lean against masonry wall, column or partition wall. Reinforced concrete or metal beams, reinforced beams, wooden structures of roof or span are leaned against masonry structures most usually. Investigations show that masonry structures under concentrated load withstand higher loads than structures of which the whole surface area is compressed. In most cases traditional bricks’ masonry under concentrated load was investigated. Its head joints are filled with mortar. This paper describes the experimental and numerical modeling results of investigation of calcium silicate hollow blocks masonry with thin layered mortar and unfilled head joints compressed by concentrated load. The more dangerous case when the edge of masonry unit (wall) is affected by concentrated load was chosen for analysis. Preliminary investigations have shown that the bed joints transmiss horizontal stresses. The stress distribution angle is close to 60°, i.e. close to stress distribution in masonry with filled head joints.eng
dc.formatPDF
dc.format.extentp. 39-45
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyDOAJ
dc.relation.isreferencedbyICONDA
dc.relation.isreferencedbyTOC Premier
dc.relation.isreferencedbyDimensions
dc.relation.isreferencedbyGale's Academic OneFile
dc.relation.isreferencedbyAcademic Search Complete
dc.rightsLaisvai prieinamas internete
dc.source.urihttps://doi.org/10.3846/est.2020.1404
dc.source.urihttps://journals.vgtu.lt/index.php/EST/article/view/14041/10342
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:82633861/datastreams/MAIN/content
dc.titleAnalysis of behaviour of calcium silicate hollow blocks masonry subjected to the concentrated load
dc.typeStraipsnis kitoje DB / Article in other DB
dcterms.accessRightsThis is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
dcterms.licenseCreative Commons – Attribution – 4.0 International
dcterms.references21
dc.type.pubtypeS3 - Straipsnis kitoje DB / Article in other DB
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.vgtuprioritizedfieldsSD0101 - Pažangios statinių konstrukcijos / Smart building structures
dc.subject.ltspecializationsL104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies
dc.subject.encalcium silicate hollow blocks
dc.subject.enconcentrated load
dc.subject.encompressive strength
dc.subject.ennumerical modeling
dcterms.sourcetitleEngineering structures and technologies