Show simple item record

dc.contributor.authorAviža, Donatas
dc.contributor.authorTurskis, Zenonas
dc.contributor.authorKaklauskas, Artūras
dc.date.accessioned2023-09-18T20:42:38Z
dc.date.available2023-09-18T20:42:38Z
dc.date.issued2015
dc.identifier.issn1392-3730
dc.identifier.other(BIS)VGT02-000030444
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/151787
dc.description.abstractA case study provides the correlation analysis of the thickness of the thermo-insulation layer (expanded polystyrene – EPS70) of the typical details of the external wall and energy performance class in a modern newly constructed residential low-energy building (one and two-room apartment). The conducted analysis focused on what impact different geographical areas of building construction and different energy performance classes of the building may had on the thickness of the thermo-insulation layer. Lithuania was chosen as the object of this study. Calculations were carried out in seven towns, including Vilnius, Klaipeda, Kaunas, Siauliai, Panevezys, Utena and Dukstas. According to requirements for legal acts passed in the Republic of Lithuania and to Directive 2010/31/EU (2010), as a result, the necessary thickness of thermo-insulation layers (EPS70) and a payback period were calculated. A multiple criteria decision support system for analyzing the correlation between the thickness of the thermo-insulation layer and its payback period of the external wall (DSS-ACTILPW) consisting of a database, a database management system, a model-base, a model-base management system and a user interface was developed. Information on the performed analysis is important to building designers, energy consumption auditors and investment experts who make the final decisions on energy efficiency of buildings in the residential building sector.eng
dc.formatPDF
dc.format.extentp. 827-835
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyAcademic Search Complete
dc.relation.isreferencedbyICONDA
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.source.urihttp://dx.doi.org/10.3846/13923730.2015.1046910
dc.subjectAE02 - Efektyvios išteklių ir energijos naudojimo sistemos bei technologijos / Efficient use of resources, energy systems and technologies
dc.titleA multiple criteria decision support system for analyzing the correlation between the thickness of a thermo-insulation layer and its payback period of the external wall
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references19
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas Kauno technologijos universitetas
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.contributor.facultyPersonalo direkcija / Human Resources Office
dc.subject.researchfieldS 003 - Vadyba / Management
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.ltspecializationsL102 - Energetika ir tvari aplinka / Energy and a sustainable environment
dc.subject.enResidential low-energy building
dc.subject.enThermo-insulation
dc.subject.enPayback period
dc.subject.enEnergy performance class
dc.subject.enCorrelation analysis
dc.subject.enEnergy efficiency of buildings
dc.subject.enExternal wall
dc.subject.enMultiple criteria decision support system
dcterms.sourcetitleJournal of civil engineering and management
dc.description.issueno. 6
dc.description.volumeVol. 21
dc.publisher.nameTechnika ; Taylor & Francis
dc.publisher.cityVilnius ; London
dc.identifier.doi000355816400013
dc.identifier.doi2-s2.0-84930809236
dc.identifier.doi10.3846/13923730.2015.1046910
dc.identifier.elaba8746498