Show simple item record

dc.contributor.authorJokūbaitis, Aidas,
dc.contributor.authorValivonis, Juozas,
dc.date.accessioned2023-12-22T07:07:16Z
dc.date.available2023-12-22T07:07:16Z
dc.date.issued2024.
dc.identifier.issn0263-8223
dc.identifier.other(crossref_id)154857371
dc.identifier.urihttps://etalpykla.vilniustech.lt/xmlui/handle/123456789/153816
dc.description.abstractCurrent design codes in North America have guidelines for assessing the anchorage zone of pretensioned fiber reinforced polymer (FRP) reinforcement. However, there is no comparison of the Eurocode approach with experimental data or suggestions for its application for prestressed FRP reinforcement. Therefore, the main objective of this article is to provide a comparison of available data in the literature on the transfer, flexural bond, and anchorage length of different types of FRP reinforcement with Eurocode and to provide insight on the adaptation of this code. The database of more than 300 and 100 specimens with the results of the transfer and flexural bond lengths is used, respectively. This database is used to derive and propose the parameters that describe the type and surface of pretensioned FRP reinforcement based on the Eurocode approach. Furthermore, the influence of shear reinforcement and the type of pretensioned reinforcement release (gradual and sudden) is taken into account. The Eurocode approach with the coefficients proposed for different FRP reinforcements on average gave the best prediction of the experimental transfer, flexural bond, and anchorage length results compared to the North American design codes for FRP reinforcement and the Eurocode for steel strands.eng
dc.formatPDF
dc.format.extentp. 1-17.
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyScopus
dc.rightsPrieinamas tik institucijos intranete.
dc.source.urihttps://www.sciencedirect.com/science/article/pii/S0263822323010589
dc.source.urihttps://talpykla.elaba.lt/elaba-fedora/objects/elaba:181790968/datastreams/MAIN/content
dc.titleAnalysis of the transfer, flexural bond and anchorage lengths of pretensioned FRP reinforcement based on Eurocode
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references38
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyStatybos fakultetas / Faculty of Civil Engineering
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.vgtuprioritizedfieldsSD0101 - Pažangios statinių konstrukcijos / Smart building structures
dc.subject.ltspecializationsL104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies
dc.subject.entransfer length
dc.subject.enflexural bond length
dc.subject.enanchorage length
dc.subject.enprestress
dc.subject.enFRP
dc.subject.enEurocode
dcterms.sourcetitleComposite structures.
dc.description.volumevol. 327
dc.publisher.nameElsevier
dc.publisher.cityOxford
dc.identifier.doi154857371
dc.identifier.doi1-s2.0-S0263822323010589
dc.identifier.doiS0263-8223(23)01058-9
dc.identifier.doi001112499200001
dc.identifier.doi10.1016/j.compstruct.2023.117712
dc.identifier.elaba181790968


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record