Study of measured indoor low-frequency noise levels resulting from outdoor noise sources, using a simplified physical model as well as empirical and FEM calculations

Thumbnail
Peržiūrėti/Atidaryti
jve_Vol18_N4_2693-2713_Saliunas.pdf (13.09Mb)
Data
2016
Autorius
Šaliūnas, Darius
Volkovas, Vitalijus
Januševičius, Tomas
Metaduomenys
Rodyti detalų aprašą
Santrauka
The paper presents an investigation simulating transformations of an acoustic field at low frequencies indoors, when the sound source is outdoors. The investigation was performed using a simplified and 5-times-smaller physical model. The paper presents measured spatial sound pressure level (SPL) distribution at 1/3 octave bands as well as at discrete frequencies (at various room modes). Measurements inside the physical model (at a total of 2,565 points) confirm that when exposed to outdoor broadband noise, low-frequency sound pressure levels at 1/3 octave bands inside the room can differ by more than 30 dB, while at discrete frequencies measured SPL can vary by 50 dB or more. Below the calculated lowest room mode, due to resonant vibrations of physical model walls, large differences in sound pressure levels inside the model (up to 20.7 dB at 100 Hz 1/3 octave band and up to 32.4 dB at discrete Hz frequencies) were found. The investigation also includes analysis of levels in the corners of physical models compared to average sound pressure levels in the whole model space or some cross-sections, which shows that sound pressure levels in corners can be up to 10 dB lower. Calculation of the indoor average sound pressure level at low frequencies according to empirical formulas specified in standard ISO 12354‑3 showed conformity between measurement and calculation results only in a part of the investigated range of frequency bands. Calculations using FEM at discrete frequencies gave more adequate results of sound pressure levels and their spatial distribution. FEM calculations proved that calculation of the average sound pressure level from measurements at points every 25 cm (every 5 cm in the physical model) can produce results close to the average of the sound pressure level of the room if it were measured at every possible position.
Paskelbimo data (metai)
2016
URI
https://etalpykla.vilniustech.lt/handle/123456789/115093
Kolekcijos
  • Straipsniai Web of Science ir/ar Scopus referuojamuose leidiniuose / Articles in Web of Science and/or Scopus indexed sources [7946]

 

 

Naršyti

Visame DSpaceRinkiniai ir kolekcijosPagal išleidimo datąAutoriaiAntraštėsTemos / Reikšminiai žodžiai InstitucijaFakultetasKatedra / institutasTipasŠaltinisLeidėjasTipas (PDB/ETD)Mokslo sritisStudijų kryptisVILNIUS TECH mokslinių tyrimų prioritetinės kryptys ir tematikosLietuvos sumanios specializacijosŠi kolekcijaPagal išleidimo datąAutoriaiAntraštėsTemos / Reikšminiai žodžiai InstitucijaFakultetasKatedra / institutasTipasŠaltinisLeidėjasTipas (PDB/ETD)Mokslo sritisStudijų kryptisVILNIUS TECH mokslinių tyrimų prioritetinės kryptys ir tematikosLietuvos sumanios specializacijos