• Lietuvių
    • English
  • English 
    • Lietuvių
    • English
  • Login
View Item 
  •   DSpace Home
  • Mokslinės publikacijos (PDB) / Scientific publications (PDB)
  • Moksliniai ir apžvalginiai straipsniai / Research and Review Articles
  • Straipsniai Web of Science ir/ar Scopus referuojamuose leidiniuose / Articles in Web of Science and/or Scopus indexed sources
  • View Item
  •   DSpace Home
  • Mokslinės publikacijos (PDB) / Scientific publications (PDB)
  • Moksliniai ir apžvalginiai straipsniai / Research and Review Articles
  • Straipsniai Web of Science ir/ar Scopus referuojamuose leidiniuose / Articles in Web of Science and/or Scopus indexed sources
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The role of air tightness in assessment of building energy performance: case study of Lithuania

Thumbnail
Date
2016
Author
Šadauskienė, Jolanta
Šeduikytė, Lina
Paukštys, Valdas
Banionis, Karolis
Gailius, Albinas
Metadata
Show full item record
Abstract
The aim of this work was to evaluate the reliability of building energy performance methodology and to determine the significance of the building air tightness. This paper presents a study on the significance of the building air tightness for 27 single-family detached houses, which were built in Central Lithuania during 2007–2011. Results of the field study and calculations indicated that air tightness of A class buildings corresponded to regulation requirements, ACH50 ≤ 0.6 (air changes per hour at a 50 Pascal pressure difference between interior and exterior). There was a large variation in respect of B and C class buildings. The 90% confidence interval of ACH50 value was between 4.17 and 8.05. The results showed that Lithuanian buildings of B and C energy performance class were not sufficiently tight. The average the air change rate, when air pressure of 50 Pa was present, was 2 times higher than the regulatory value (ACH50 = 3 air change per hour). This work presents the ACH50 values' distribution according to the qualifying indicator Cq for A, B, C class buildings. Part of the presented ACH50 values of B class buildings are close to the value applicable to C class buildings. When air tightness of the buildings is evaluated, B energy performance class buildings can turn out to be C class. Results of an existing building's energy performance calculations are reliable only after verifying that the building is air tight. Otherwise, the actual heating energy consumption in buildings can significantly differ from the value calculated as per regulations if air tightness is ignored.
Issue date (year)
2016
URI
https://etalpykla.vilniustech.lt/handle/123456789/115279
Collections
  • Straipsniai Web of Science ir/ar Scopus referuojamuose leidiniuose / Articles in Web of Science and/or Scopus indexed sources [7946]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization

My Account

LoginRegister