Rodyti trumpą aprašą

dc.contributor.authorBarzdėnas, Vaidotas
dc.contributor.authorVasjanov, Aleksandr
dc.date.accessioned2023-09-18T16:39:52Z
dc.date.available2023-09-18T16:39:52Z
dc.date.issued2023
dc.identifier.issn1335-3632
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/115664
dc.description.abstractHigh-speed and high-frequency PCB interconnect solutions with the slightest discontinuities in the physical geometry along the microstrip transmission line can significantly degrade the integrity of the signal being transferred. This paper presents an analysis of SMT component pads and their impact on the successive transmission line impedance. During 0805, 1206 and 2512 package size SMT component pad discontinuity evaluations it was spotted, that the increasing deviation from target impedance affects the microstrip impedance segment following the discontinuity. A 25 Ω impedance offset at the SMT pad reduces the line impedance afterwards by up to 7 Ω. A 37 Ω impedance offset results in a microstrip impedance reduction by up to 15 Ω, whereas a 45 Ω impedance change leads to a reduction of successive segment impedance by up to 30 Ω. This effect is also present in multiple evenly-spaced discontinuities. But a single reference plane cut-out, which is twice as wide as the SMT component discontinuity, substantially improves the overall impedance of the transmission line, including the successive line segment impedance drop.eng
dc.formatPDF
dc.format.extentp. 122-126
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyDimensions
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyJ-Gate
dc.source.urihttps://sciendo.com/pl/journal/jee?tab=zeszyty
dc.titleAnalysis of SMT component land pad discontinuity effect on the overall transmission line impedance in high-speed applications
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references14
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyElektronikos fakultetas / Faculty of Electronics
dc.subject.researchfieldT 001 - Elektros ir elektronikos inžinerija / Electrical and electronic engineering
dc.subject.studydirectionE09 - Elektronikos inžinerija / Electronic engineering
dc.subject.vgtuprioritizedfieldsIK0202 - Išmaniosios signalų apdorojimo ir ryšių technologijos / Smart Signal Processing and Telecommunication Technologies
dc.subject.ltspecializationsL106 - Transportas, logistika ir informacinės ir ryšių technologijos (IRT) / Transport, logistic and information and communication technologies
dc.subject.enSMT discontinuity
dc.subject.enland pad discontinuity
dc.subject.enimpedance compensation
dc.subject.encut-out
dcterms.sourcetitleJournal of Electrical Engineering-Elektrotechnicky Casopis
dc.description.issueiss. 2
dc.description.volumevol. 74
dc.publisher.nameSlovak University of Technology
dc.publisher.cityBratislava
dc.identifier.doi000984826100007
dc.identifier.doi10.2478/jee-2023-0016
dc.identifier.elaba163467309


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą