Show simple item record

dc.contributor.authorLinkel, Artūras
dc.contributor.authorGriškevičius, Julius
dc.contributor.authorShippen, James
dc.contributor.authorMay, Barbara
dc.contributor.authorDaunoravičienė, Kristina
dc.date.accessioned2023-09-18T16:50:01Z
dc.date.available2023-09-18T16:50:01Z
dc.date.issued2016
dc.identifier.other(BIS)VGT02-000032762
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/117370
dc.description.abstractOne of most common ways to examine the quality of the patient’s upper extremity (UE) function is measuring the movement’s kinematic parameters during the motion. However, is it reliable to compare a patient’s UE motions data with healthy people’s characteristic parameters? In this paper is shown that intrapersonal coefficient of variability (CV) in angles amplitudes differs from 3.2% during elbow flexion to 52.9% during wrist abduction and CV in angular velocity differs from 22.1% during shoulder abduction to 66.3% during wrist abduction.eng
dc.formatPDF
dc.format.extentp. 73-75
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.source.urihttp://biomdlore.vgtu.lt/index.php/biomdlore/2016/paper/viewFile/95/50
dc.subjectMC01 - Biomechatroninės sistemos / Biomechatronical systems
dc.titleCharacteristic upper extremity kinematic parameters of healthy people during defined motions
dc.typeStraipsnis recenzuotame konferencijos darbų leidinyje / Paper published in peer-reviewed conference publication
dcterms.references14
dc.type.pubtypeP1d - Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionCoventry University
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldM 001 - Medicina / Medicine
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.ltspecializationsL105 - Sveikatos technologijos ir biotechnologijos / Health technologies and biotechnologies
dc.subject.enupper extremity
dc.subject.enobjective parameters
dc.subject.enmotion capturing system
dc.subject.enbiomechanics
dcterms.sourcetitleProceedings of 11th international conference "BIOMDLORE 2016", October 20-22, 2016, Druskininkai, Lithuania
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.doi10.3846/biomdlore.2016.19
dc.identifier.elaba20267807


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record