| dc.contributor.author | Linkel, Artūras | |
| dc.contributor.author | Griškevičius, Julius | |
| dc.contributor.author | Shippen, James | |
| dc.contributor.author | May, Barbara | |
| dc.contributor.author | Daunoravičienė, Kristina | |
| dc.date.accessioned | 2023-09-18T16:50:01Z | |
| dc.date.available | 2023-09-18T16:50:01Z | |
| dc.date.issued | 2016 | |
| dc.identifier.other | (BIS)VGT02-000032762 | |
| dc.identifier.uri | https://etalpykla.vilniustech.lt/handle/123456789/117370 | |
| dc.description.abstract | One of most common ways to examine the quality of the patient’s upper extremity (UE) function is measuring the movement’s kinematic parameters during the motion. However, is it reliable to compare a patient’s UE motions data with healthy people’s characteristic parameters? In this paper is shown that intrapersonal coefficient of variability (CV) in angles amplitudes differs from 3.2% during elbow flexion to 52.9% during wrist abduction and CV in angular velocity differs from 22.1% during shoulder abduction to 66.3% during wrist abduction. | eng |
| dc.format | PDF | |
| dc.format.extent | p. 73-75 | |
| dc.format.medium | tekstas / txt | |
| dc.language.iso | eng | |
| dc.source.uri | http://biomdlore.vgtu.lt/index.php/biomdlore/2016/paper/viewFile/95/50 | |
| dc.subject | MC01 - Biomechatroninės sistemos / Biomechatronical systems | |
| dc.title | Characteristic upper extremity kinematic parameters of healthy people during defined motions | |
| dc.type | Straipsnis recenzuotame konferencijos darbų leidinyje / Paper published in peer-reviewed conference publication | |
| dcterms.references | 14 | |
| dc.type.pubtype | P1d - Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings | |
| dc.contributor.institution | Vilniaus Gedimino technikos universitetas | |
| dc.contributor.institution | Coventry University | |
| dc.contributor.faculty | Mechanikos fakultetas / Faculty of Mechanics | |
| dc.subject.researchfield | M 001 - Medicina / Medicine | |
| dc.subject.researchfield | T 009 - Mechanikos inžinerija / Mechanical enginering | |
| dc.subject.ltspecializations | L105 - Sveikatos technologijos ir biotechnologijos / Health technologies and biotechnologies | |
| dc.subject.en | upper extremity | |
| dc.subject.en | objective parameters | |
| dc.subject.en | motion capturing system | |
| dc.subject.en | biomechanics | |
| dcterms.sourcetitle | Proceedings of 11th international conference "BIOMDLORE 2016", October 20-22, 2016, Druskininkai, Lithuania | |
| dc.publisher.name | Technika | |
| dc.publisher.city | Vilnius | |
| dc.identifier.doi | 10.3846/biomdlore.2016.19 | |
| dc.identifier.elaba | 20267807 | |