Rodyti trumpą aprašą

dc.contributor.authorGriškevičius, Julius
dc.contributor.authorApanskienė, Vigita
dc.contributor.authorŽižienė, Jurgita
dc.contributor.authorDaunoravičienė, Kristina
dc.contributor.authorOvčinikova, Agnė
dc.contributor.authorKizlaitienė, Rasa
dc.contributor.authorSereikė, Ieva
dc.contributor.authorKaubrys, Gintaras
dc.contributor.authorPauk, Jolanta
dc.contributor.authorIdźkowski, Adam
dc.date.accessioned2023-09-18T16:50:04Z
dc.date.available2023-09-18T16:50:04Z
dc.date.issued2016
dc.identifier.other(BIS)VGT02-000032764
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/117377
dc.description.abstractMultiple sclerosis (MS) is the most frequent neurological disease causing permanent disability in young adults. Subtle walking difficulties, such as reduced walking speed, step length, cadence and increased step width can be detected at an early stage of the disease. Main goal of this research is by using non-invasive wireless inertial sensors measure gait of MS patients in clinical setting and extract temporal biomechanical parameters that would allow objectively evaluate level of disability in MS patients. Analysis of 25-Foot walk showed that the duration of stance phase is approximately 1.6 times greater in MS group than in healthy control group, while the duration of swing phase in MS group is 1.3 times longer. In general, the MS patients are walking approximately 1.6 times slower.eng
dc.formatPDF
dc.format.extentp. 80-82
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.source.urihttp://biomdlore.vgtu.lt/index.php/biomdlore/2016
dc.subjectMC01 - Biomechatroninės sistemos / Biomechatronical systems
dc.titleEstimation of temporal gait parameters of multiple sclerosis patients in clinical setting using inertial sensors
dc.typeStraipsnis recenzuotame konferencijos darbų leidinyje / Paper published in peer-reviewed conference publication
dcterms.references8
dc.type.pubtypeP1d - Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionVĮ Vilniaus universiteto ligoninės Santariškių klinikos
dc.contributor.institutionBialystok University of Technology
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldM 001 - Medicina / Medicine
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.researchfieldT 010 - Matavimų inžinerija / Measurement engineering
dc.subject.ltspecializationsL105 - Sveikatos technologijos ir biotechnologijos / Health technologies and biotechnologies
dc.subject.enMultiple sclerosis
dc.subject.enGait
dc.subject.enInertial sensors
dc.subject.enBiomechanics
dcterms.sourcetitleProceedings of 11th international conference "BIOMDLORE 2016", October 20–22, 2016, Druskininkai, Lithuania
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.doi10.3846/biomdlore.2016.21
dc.identifier.elaba20270049


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą