Workability of glass reinforced concrete (GRC) with granite and silica sand aggregates
Data
2017Autorius
Moceikis, Rimvydas
Kičaitė, Asta
Keturakis, Evaldas
Metaduomenys
Rodyti detalų aprašąSantrauka
In this paper, GRC premix recipes including fine granite and silica sands, reinforced with 13mm length alkali resistant glass fibers are investigated. Two CEM I 52,5R cements with different particle sizes were used and severe water dissociation noticed in one of concrete mixes. Cement particle size distribution determined with laser diffraction particle analyser Cilas 1090LD. To determine modulus of rupture (M.O.R.) and limit of proportionality (L.O.P), plates thickness 15 and 20 mm were produced and tested for flexural resistance according to 4-point bending scheme. Concrete workability tests were made according EN 1170-1.