dc.description.abstractThe main sources of measurement uncertainty in long-stroke line scales are line detection errors and external factors, especially temperature effects. The number of calibration errors of this type increases with the lengthening of the calibration time. Therefore, dynamic methods of line scale detection for modern long-stroke line scale comparators are used [1, 2, 3, 7]. The article describes the dynamic method of line scale detection by means of an optical microscope equipped with a photosensitive cell matrix and a line scale detection algorithm. A measurement uncertainty estimate of the dynamic method for calibration of long-stroke line scales has been created [4, 5, 7]. The method’s error correlations with the detection rate, number of rated lines, measuring rate, and exposure delay are described. Optimal values of these parameters are estimated. When applying the dynamic method to calibration of long grating scales under the existing industrial conditions, evenness of illumination becomes an important factor of accuracy of the detection of line position, which has been one of the main sources of inaccuracy in conventional measurements. Analytical and experiential distributions of illumination were tested as a function of exposure time and pattern influence to the calibration error. The method of reducing this error was analyzed, implemented and tested on the longstroke line scale comparator, which has been developed and realized at JSC Precizika Metrology in cooperation with the Kaunas University of Technology and the Vilnius Gediminas Technical University.eng
dc.format.extentp. 159-163
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyCambridge Scientific Abstracts - Conference Papers Index
dc.relation.isreferencedbyINSPEC
dc.relation.isreferencedbyCompendex
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyVINITI
dc.titleAnalysis of the dynamic method of line scale detection parameters
dc.typeStraipsnis konferencijos darbų leidinyje Scopus DB / Paper in conference publication in Scopus DB
dcterms.references7
dc.type.pubtypeP1b - Straipsnis konferencijos darbų leidinyje Scopus DB / Article in conference proceedings Scopus DB
dc.contributor.institutionUAB "Precizika metrology"
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldT 010 - Matavimų inžinerija / Measurement engineering
dc.subject.enLong granting scale calibration
dc.subject.enDynamic method
dc.subject.enEvenness of illumination
dc.subject.enMeasurement uncertainty
dcterms.sourcetitleREM 2008 : 9th international workshop on research and education in mechatronics, September 18th-19th 2008, Bergamo, Italy
dc.publisher.nameUniversity of Bergamo
dc.publisher.cityBergamo
dc.identifier.elaba3949300


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą