Analysis of 4-mm DSR tests: calibration, sample preparation, and evaluation of repeatability and reproducibility
Date
2021Author
Škulteckė, Judita
Soenen, Hilde
Blom, Johan
Vaitkus, Audrius
Židanavičiūtė, Jurgita
Margaritis, Alexandros
Metadata
Show full item recordAbstract
Rheological characterisation methods are important when it comes to a performance-based selection system for bituminous binders for road applications. Standardised methods exist for the determination of bitumen rheological behaviour based on a dynamic shear rheometer (DSR) at intermediate and high service temperatures and a bending beam rheometer (BBR) at low temperatures. Recently, a dynamic shear rheometer with 4mm parallel plates (4-mm DSR), has been proposed by Western Research Institute (WRI), as a promising method to determine the rheological behaviour at low temperatures. Clear advantages of the 4-mm DSR are related to the small sample size, especially important for recovered and aged binders, and the ability to work with adequate stresses at very low temperatures. Furthermore, if 4-mm DSR can be used to assess the low temperature behaviour of bitumen, then the performance of a binder in the whole range of service temperatures, could be assessed by just one equipment, a DSR. This paper focuses on the challenges related to 4-mm DSR tests regarding equipment preparation, with a specific attention to the temperature assessment and calibration. Furthermore, a sample preparation method, assuring good adhesion to both plates is proposed and the repeatability and reproducibility of 4-mm DSR tests is evaluated.