Rodyti trumpą aprašą

dc.contributor.authorŠkulteckė, Judita
dc.contributor.authorSoenen, Hilde
dc.contributor.authorBlom, Johan
dc.contributor.authorVaitkus, Audrius
dc.contributor.authorŽidanavičiūtė, Jurgita
dc.contributor.authorMargaritis, Alexandros
dc.date.accessioned2023-09-18T19:08:03Z
dc.date.available2023-09-18T19:08:03Z
dc.date.issued2021
dc.identifier.issn1468-0629
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/135779
dc.description.abstractRheological characterisation methods are important when it comes to a performance-based selection system for bituminous binders for road applications. Standardised methods exist for the determination of bitumen rheological behaviour based on a dynamic shear rheometer (DSR) at intermediate and high service temperatures and a bending beam rheometer (BBR) at low temperatures. Recently, a dynamic shear rheometer with 4mm parallel plates (4-mm DSR), has been proposed by Western Research Institute (WRI), as a promising method to determine the rheological behaviour at low temperatures. Clear advantages of the 4-mm DSR are related to the small sample size, especially important for recovered and aged binders, and the ability to work with adequate stresses at very low temperatures. Furthermore, if 4-mm DSR can be used to assess the low temperature behaviour of bitumen, then the performance of a binder in the whole range of service temperatures, could be assessed by just one equipment, a DSR. This paper focuses on the challenges related to 4-mm DSR tests regarding equipment preparation, with a specific attention to the temperature assessment and calibration. Furthermore, a sample preparation method, assuring good adhesion to both plates is proposed and the repeatability and reproducibility of 4-mm DSR tests is evaluated.eng
dc.formatPDF
dc.format.extentp. 557-571
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyScopus
dc.relation.isreferencedbyScience Citation Index Expanded (Web of Science)
dc.source.urihttps://doi.org/10.1080/14680629.2019.1634636
dc.source.urihttps://www.tandfonline.com/doi/full/10.1080/14680629.2019.1634636
dc.titleAnalysis of 4-mm DSR tests: calibration, sample preparation, and evaluation of repeatability and reproducibility
dc.typeStraipsnis Web of Science DB / Article in Web of Science DB
dcterms.references16
dc.type.pubtypeS1 - Straipsnis Web of Science DB / Web of Science DB article
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionNynas NV
dc.contributor.institutionAntwerp University
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 002 - Statybos inžinerija / Construction and engineering
dc.subject.vgtuprioritizedfieldsSD0101 - Pažangios statinių konstrukcijos / Smart building structures
dc.subject.ltspecializationsL104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies
dc.subject.endynamic shear rheometer
dc.subject.enDSR
dc.subject.enlow temperature
dc.subject.enrepeatability
dc.subject.enreproducibility
dc.subject.en4-mm parallel plates
dcterms.sourcetitleRoad materials and pavement design
dc.description.issueno. 3
dc.description.volumevol. 22
dc.publisher.nameTaylor & Francis
dc.publisher.cityLondon
dc.identifier.doi000474437400001
dc.identifier.doi2-s2.0-85068541047
dc.identifier.doi10.1080/14680629.2019.1634636
dc.identifier.elaba39835633


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą