Rodyti trumpą aprašą

dc.contributor.authorBūga, Arūnas
dc.contributor.authorJokela, Jorma
dc.contributor.authorPutrimas, Raimundas
dc.contributor.authorZigmantienė, Evelina
dc.date.accessioned2023-09-18T19:12:51Z
dc.date.available2023-09-18T19:12:51Z
dc.date.issued2011
dc.identifier.other(BIS)VGT02-000024930
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/136633
dc.description.abstractCalibration laboratory of Institute of Geodesy, VGTU was established in year 2000. Laboratory is accredited for EDM instruments calibration by Lithuanian National Accreditation Bureau since 2001-09-20. Laboratory fulfils LST EN ISO/IEC 17025:2005 standards. Calibration of EDM instruments is performed at Kyviškės calibration baseline. The baseline consists of six observation pillars at intervals from 20 to 1320 meters. Seventh pillar was built for baseline extension and possibility of angular measurements. Accuracy of baseline is 0,2 ÷1,2 mm. Calibration laboratory performs EDM instruments verification and calibration at the Kyviškės Calibration Baseline. Statistic of EDM instruments calibration used in Lithuania are presented. Regularity of calibration in Lithuania - 2 years. Statistical analysis of calibration results is presented. Over 60 total stations instruments are calibrated every year. Stability of Kyviškės calibration baseline is analysed and confirmed. Every 5 years Kyviškės calibration baseline is calibrated by specialists of Finnish Geodetic Institute.eng
dc.format.extentp. 1301-1305
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.source.urihttp://leidykla.vgtu.lt/conferences/Enviro2011/Articles/6/1301_1305_Buga_others.pdf
dc.titleAnalysis of EDM instruments calibration at the Kyviškės calibration baseline
dc.typeStraipsnis recenzuotame konferencijos darbų leidinyje / Paper published in peer-reviewed conference publication
dcterms.references12
dc.type.pubtypeP1d - Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.institutionFinnish Geodetic Institute
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 010 - Matavimų inžinerija / Measurement engineering
dc.subject.enGeodetic baseline
dc.subject.enCalibration
dc.subject.enEDM
dc.subject.enTotal station
dcterms.sourcetitle8th International Conference "Environmental Engineering", May 19-20, 2011, Villnius, Lithuania CD
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.elaba3989622