Rodyti trumpą aprašą

dc.contributor.authorProkopovič, Valdemar
dc.contributor.authorMokšin, Vadim
dc.contributor.authorKilikevičius, Artūras
dc.contributor.authorGedvila, Andrius
dc.date.accessioned2023-09-18T19:42:52Z
dc.date.available2023-09-18T19:42:52Z
dc.date.issued2013
dc.identifier.issn1822-2951
dc.identifier.other(BIS)VGT02-000026591
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/142441
dc.description.abstractPneumatic artificial muscles (PAMs) are used in various industrial applications due to their simple construction, lightweight, hig force to weight ratio and usage in rough environments. Their fast response to the change of air pressure also is appreciated. In most cases PAMs are used only as force generating actuators. However PAMs present a great potential for use in robotics applications as artificial hands of robots or other positioning mechanisms. In such applications the positioning accuracy of the links becomes extremely important. This paper presents results of measurements of positioning accuracy of Festo MAS-20-200N-AA-MC-O PAM in both pressurized and depressurized states. The dependence of positioning accuracy on air pressure and external muscle load is established. It is also observed that PAM exhibits creeping movement, which depends on air pressure and external muscle load.eng
dc.format.extentp. 204-207
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyAcademic Search Complete
dc.relation.isreferencedbyConference Proceedings Citation Index (nenaudotinas)
dc.titleExperimental research of positioning accuracy of pneumatic artificial muscle
dc.typeStraipsnis konferencijos darbų leidinyje Web of Science DB / Paper in conference publication in Web of Science DB
dcterms.references7
dc.type.pubtypeP1a - Straipsnis konferencijos darbų leidinyje Web of Science DB / Article in conference proceedings Web of Science DB
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyMechanikos fakultetas / Faculty of Mechanics
dc.subject.researchfieldT 009 - Mechanikos inžinerija / Mechanical enginering
dc.subject.enPneumatic artificial muscle
dc.subject.enPositioning accuracy
dc.subject.enPosition repeatability
dcterms.sourcetitleMechanika'2013 : proceedings of the 18th international conference, 4, 5 April, 2013, Kaunas University of Technology, Lithuania
dc.publisher.nameTechnologija
dc.publisher.cityKaunas
dc.identifier.elaba4026577


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą