Investigation of the efficiency of vibro-isolating supports of optical tables
![Thumbnail](/bitstream/handle/123456789/146306/ajase_Vol3_No1_20-25_moksin.pdf.jpg?sequence=3&isAllowed=y)
Peržiūrėti/ Atidaryti
Data
2014Autorius
Vekteris, Vladas
Kilikevičius, Artūras
Mokšin, Vadim
Gedvila, Andrius
Metaduomenys
Rodyti detalų aprašąSantrauka
The main tasks of this work are to investigate experimentally the vibration behaviour of the optical tables and the floor structure and to establish the vibration transmission factor of vibro-isolating supports. It is established that the vibration frequency of the table is low, about 1 Hz. Therefore it is possible to mount the laser and optomechanical convergence system of multiple pump beams to the optical table, because the transmission factor of vibro-isolating supports varies from 0.879 to 0.968.