Rodyti trumpą aprašą

dc.contributor.authorJakimavičiūtė Maselienė, Vaidotė
dc.contributor.authorMažeika, Jonas
dc.contributor.authorPetrošius, Rimantas
dc.contributor.authorSkuratovič, Žana
dc.date.accessioned2023-09-18T20:05:20Z
dc.date.available2023-09-18T20:05:20Z
dc.date.issued2011
dc.identifier.other(BIS)LBT02-000043611
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/146672
dc.description.abstractIAEA safety documents (Safety standarts… 1994; 1999a; 1999b) recommend assessing the safety framework of groundwater exploitation in the proximity of nuclear facilities. The main task of this study is to assess the results on the re-calculation of Visaginas town wellfield well protection zones (WPZ), since the Visaginas town wellfield is installed close to Ignalina Nuclear Power Plant (INPP) site and other sites of existing or planed new nuclear facilities. The numerical model used in this study is based on three-dimensional finite-element code FEFLOW 5.0 which allows modeling of groundwater flow and contaminant transport in a layered threedimensional system. The calibrated model of Visaginas wellfield area simulated the groundwater flow in the Quaternary and Upper-Middle Devonian aquifers systems. The evaluation of well protection zones for wellfields exploiting groundwater is currently determined by the Lithuanian legal documents (HN 44:2006). As a result of modeling the groundwater formation sources were specified and dimensions of wells protection zones in sectors 3a and 3b were established. The groundwater modeling results of this study shows that the third sub-zone (3b) of WPZ should be 0.6-1.1 km away from the wellfield fence. The long axis of WPZ extends for 4 250 m from north to south and for approximately 3 250 m from east to west. Visaginas wellfield capture zone during 50 years operation would reach the site for planned near-surface repository for radioactive waste in case of hypothetical very high wellfield capacity more than 70 000 m3/day.eng
dc.format.extentP. 127-133
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyConference Proceedings Citation Index (nenaudotinas)
dc.source.urihttp://leidykla.vgtu.lt/conferences/Enviro2011/Articles/1/127_133_Jakimaviciute_others.pdf
dc.titleHydrogeology model of Ignalina region for Visaginas well field protection zone substantiation
dc.typeStraipsnis konferencijos darbų leidinyje Web of Science DB / Paper in conference publication in Web of Science DB
dcterms.references18
dc.type.pubtypeP1a - Straipsnis konferencijos darbų leidinyje Web of Science DB / Article in conference proceedings Web of Science DB
dc.contributor.institutionGamtos tyrimų centras Vilniaus Gedimino technikos universitetas
dc.contributor.institutionGamtos tyrimų centras
dc.subject.researchfieldN 005 - Geologija / Geology
dc.subject.enWellfield
dc.subject.enCapture zone
dc.subject.enAquifer
dc.subject.enFinite elements model
dcterms.sourcetitleEnvironmental engineering : the 8th international conference : selected papers : May 19-20, 2011, Vilnius, Lithuania. Vol. 1