Rodyti trumpą aprašą

dc.contributor.authorRimeika, Mindaugas
dc.contributor.authorAlbrektienė-Plačakė, Ramunė
dc.date.accessioned2023-09-18T20:08:14Z
dc.date.available2023-09-18T20:08:14Z
dc.date.issued2014
dc.identifier.other(BIS)VGT02-000029121
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/146986
dc.description.abstractApparent losses are the nonphysical losses that occur when water is successfully delivered to the customer but, for various reasons, is not measured or recorded accurately, thereby including a degree of error in the amount of customer consumption. According to data from the Lithuanian Water Supply Association, in 2012 about 124 mln. m³ of ground water was supplied to the network, but only 92 mln. m³ of it was sold, while the remaining share represented water losses – 32 mln. m³ per year. An average water loss level in Lithuania is 30%, varying from 53% to 15%. Local water utilities take a little care of apparent water losses, as they account for about 20–30% of the total water losses. This article deals with an investigation of apparent losses in Alytus city, Lithuania. The article highlights the significance of apparent losses and explains possible options for the control of these losses in order to recover revenue in systems with metered customers. One test was carried out with bulk water meters at blockhouses, using Class B and C water meters constructed sequentially. The other test was carried out at apartments of blockhouses, where new Class C flow meters are installed. Both tests showed a significant volume of apparent water losses due to inaccuracy of used flow meters. An average calculated pay-back period for the installation of Class C water meters is about 1 year.eng
dc.formatPDF
dc.format.extentp. 1-6
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.source.urihttp://dx.doi.org/10.3846/enviro.2014.090
dc.subjectAE01 - Aplinkos sistemos ir aplinkos apsaugos technologijos / Environmental systems and environment protection technologies
dc.titleAnalysis of apparent water losses, case study
dc.typeStraipsnis recenzuotame konferencijos darbų leidinyje / Paper published in peer-reviewed conference publication
dcterms.references6
dc.type.pubtypeP1d - Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineering
dc.subject.researchfieldT 004 - Aplinkos inžinerija / Environmental engineering
dc.subject.ltspecializationsL104 - Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies
dc.subject.enApparent water losses
dc.subject.enAccuracy of water meters
dc.subject.enFlow meter
dcterms.sourcetitle9th International Conference "Environmental Engineering", May 22-23, 2014, Vilnius, Lithuania: selected papers CD
dc.publisher.nameTechnika
dc.publisher.cityVilnius
dc.identifier.doi10.3846/enviro.2014.090
dc.identifier.elaba4094875


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą