Rodyti trumpą aprašą

dc.contributor.authorGudiškis, Andrius
dc.contributor.authorSerackis, Artūras
dc.date.accessioned2023-09-18T20:38:08Z
dc.date.available2023-09-18T20:38:08Z
dc.date.issued2014
dc.identifier.other(BIS)VGT02-000030205
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/151511
dc.description.abstractThe location of the heart beats in ECG signals are easily detectable by QRS detectors. However the quality of the ECG signal may vary considerably over time. There could be various sources of distortions that changes the shape of the ECG signal and makes some parts of the signal not readable. The QRS detector usually finds additional QRS complexes that are actually not present in the ECG signal. Paper presents effective algorithm to reduce the amount of false heart beat detections together with the algorithm to adjust heart beat position in noisy signal according to blood pressure measurements.eng
dc.formatPDF
dc.format.extentp. 1-4
dc.format.mediumtekstas / txt
dc.language.isoeng
dc.relation.isreferencedbyIEEE Xplore
dc.relation.isreferencedbyConference Proceedings Citation Index - Science (Web of Science)
dc.source.urihttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7020315&filter%3DAND%28p_IS_Number%3A7020310%29
dc.subjectIK04 - Skaitmeninės signalų apdorojimo technologijos / Digital signal processing technologies
dc.titleHeart beat prediction in distorted ECG signal using blood pressure measurements
dc.typeStraipsnis konferencijos darbų leidinyje Web of Science DB / Paper in conference publication in Web of Science DB
dcterms.references0
dc.type.pubtypeP1a - Straipsnis konferencijos darbų leidinyje Web of Science DB / Article in conference proceedings Web of Science DB
dc.contributor.institutionVilniaus Gedimino technikos universitetas
dc.contributor.facultyElektronikos fakultetas / Faculty of Electronics
dc.subject.researchfieldT 001 - Elektros ir elektronikos inžinerija / Electrical and electronic engineering
dc.subject.researchfieldT 007 - Informatikos inžinerija / Informatics engineering
dc.subject.ltspecializationsL106 - Transportas, logistika ir informacinės ir ryšių technologijos (IRT) / Transport, logistic and information and communication technologies
dc.subject.enECG signal quality
dc.subject.enECG signal shape
dc.subject.enQRS complexes
dc.subject.enQRS detectors
dc.subject.enNoisy signal
dc.subject.enHeart beat position
dcterms.sourcetitle2014 IEEE 2nd Workshop on advances in information, electronic and electrical engineering (AIEEE), proceedings of the 2nd workshop November 28–29, 2014 Vilnius, Lithuania
dc.publisher.nameIEEE
dc.publisher.cityWashington
dc.identifier.doi000389270700002
dc.identifier.doi10.1109/AIEEE.2014.7020315
dc.identifier.elaba8366931


Šio įrašo failai

FailaiDydisFormatasPeržiūra

Su šiuo įrašu susijusių failų nėra.

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą