An investigation of the automatic relative gravimeters

Thumbnail
Date
2013
Author
Paršeliūnas, Eimuntas Kazimieras
Petroškevičius, Petras
Obuchovski, Romuald
Birvydienė, Rosita
Metadata
Show full item record
Abstract
The laboratory and field investigations of the several automatic gravimeters Scintrex CG_5 with a quartz elastic system used for the determining of gravity acceleration were performed. Research on characteristics of four gravimeters includes a five-year period. The data consists of gravimetric observations at a laboratory, on the gravimetric testline and at the points of the Lithuanian gravimetric network. The evaluation of the phenomena of the spring systems of the gravimeters was made. The stress on the estimation of the zero drift at a laboratory and field investigations was done. It was detected that zero drift does not exceed 500 μGal per day with a diapason of 200 μGal. The zero drifts per hour do not exceed 25 μGal, mostly they are under 10 μGal. According to the annual calibration results the character of the changes of the linear scale coefficients of the gravimeters were analysed too. The calibration base of 270 km length in Lithuania where the difference of the gravity acceleration of the end points is 201 mGal was used for investigations. The research showed that the biggest deviation from the unit of the linear scale coefficients does not exceed 0.013. It was noted, that the values of the linear scale coefficients of the gravimeters have a tendency to decrease. Also was noted, that the values of the linear scale coefficients have a tendency to decrease in the period between field works, and to increase - in the field works period. So the calibration of the gravimeters should be carried out before and after the field works. Based on measurements carried out during development of the Lithuanian gravimetric network, which consists of 686 gravimetric points, accuracy of gravity acceleration increments was assessed. The comparison of the observations results against the results, obtained by the LaCoste and Romberg gravimeters with metal elastic system, is presented too.
Issue date (year)
2013
URI
https://etalpykla.vilniustech.lt/handle/123456789/140440
Collections
  • Konferencijų straipsniai / Conference Articles [15192]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization

My Account

LoginRegister