Investigation of the overvoltage in the inverter caused by the motor deceleration

Thumbnail
Date
2009
Author
Baškys, Algirdas
Bleizgys, Vytautas
Zlosnikas, Valerijus
Metadata
Show full item record
Abstract
The overvoltage in the inverter that supplies the AC induction motor, which during the deceleration operates as a generator delivering current back into the inverter DC bus, has been investigated. The investigation was performed using a special test bench. The impact of the motor deceleration rate, motor load and initial rotation velocity, at which the deceleration starts, on the overvoltage was investigated and analyzed. The obtained results vvere employed for the development of the DC bus overvoltage fault protection of the inverter.
Issue date (year)
2009
URI
https://etalpykla.vilniustech.lt/handle/123456789/150242
Collections
  • Konferencijų straipsniai / Conference Articles [15192]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization

My Account

LoginRegister