Daugiabučių pastatų mikroklimato parametrų tyrimas

Thumbnail
Date
2015
Author
Ankėnas, Vilius
Motuzienė, Violeta
Metadata
Show full item record
Abstract
Nagrinėjama tinkamų mikroklimato parametrų užtikrinimo šaltuoju metų laiku problema įvairių statybos metų daugiabučiuose pastatuose. Šiame straipsnyje yra aprašomas 19 butų, kuriuose įrengta naturali vėdinimo sistema, mikroklimato parametrų tyrimas, kurio metu matuoti šie patalpų oro rodikliai: CO2 koncentracija patalpų ore, oro temperatura bei santykinė drėgmė. Matavimų rezultatai parodė, jog dauguma daugiabučių pastatų butų yra vėdinami nepakankamai, nes matuotų laikotarpiu CO2 koncentracijos patalpų ore nuolat viršijo rekomenduojama riba, o apskaiciuota bendra butų oro apykaitos reikšmė buvo mažesnė už norminę. Gyvenamųjų patalpų oro temperaturos matavimai parodė, jog didžioji dalis higienos normas viršijancių reikšmių užfiksuota senos statybos daugiabučių namu butuose, kuriuose nėra šildymo prietaisų reguliavimo galimybės. Santykinės oro drėgmės matavimai didesnių nukrypimų neparodė ir daugelyje butų matuotu laikotarpiu pateko i higienos normose nurodytas ribas.
 
In the apartment buildings one of the most important problem is to ensure suitable microclimate parameters during the winter season. This article describes microclimate parameters study of the 19 apartments where natural ventilation system is installed. In this study the following indicators of air were measured: CO2 concentration in indoor air, air temperature and also relative humidity. Measurements showed that the majority of apartments are insufficiently ventilated because measured CO2 concentration values in indoor air consistently exceeded the recommended limit and the estimated total value of air circulation in apartments was lower than standard. Indoor air temperature measurements showed that the majority of hygiene standards exceeded values were captured in old construction building flats where were no heating control option. Relative humidity measurements did not show any significant deviations and in most apartments comfort requirements were satisfied during the entire measurement period.
 
Issue date (year)
2015
URI
https://etalpykla.vilniustech.lt/handle/123456789/151333
Collections
  • Konferencijų straipsniai / Conference Articles [15192]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization