Show simple item record

dc.rights.licenseKūrybinių bendrijų licencija / Creative Commons licenceen_US
dc.contributor.authorRubcov, Artur
dc.contributor.authorPaulauskaitė, Sabina
dc.contributor.authorMisevičiūtė, Violeta
dc.date.accessioned2024-10-17T10:22:40Z
dc.date.available2024-10-17T10:22:40Z
dc.date.issued2017
dc.identifier.issn2029-7092en_US
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/155294
dc.description.abstractThe paper provides the results of experimental tests of a wavy fin and tube heat exchanger used to heat (cool) air in a ventilation system when the wavy fin of the heat exchanger is dry and wet. The experimental tests, performed in the range of 1000<Re<4500 of the Reynolds number, determined the dependency of the heat transfer coefficient on the amount of supplied air with the varying geometry of the heat exchanger (the number of tube rows, the distance between fins, the thickness of the fin and the diameter of the tube). The experimental tests were performed on 9 heat exchangers in heating mode (dry fin) and 6 heat exchangers in cooling mode (wet fin). The ratio of heat transfer coefficient values when the fin is dry and wet varies from 0.79 to 1.12. After processing the results of the experimental tests, equations defining the dependency of the heat transfer coefficient on the amount of air and varying geometric parameters of the heat exchanger were derived, based on which 86% to 88% of the results do not exceed the 10% tolerance margin and the standard deviation varies from 3.5% to 4.3%.en_US
dc.format.extent8 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/154497en_US
dc.rightsAttribution-NonCommercial 4.0 Internationalen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/en_US
dc.source.urihttp://enviro.vgtu.lt/index.php/enviro/2017/paper/view/260en_US
dc.subjectAir-to-water heat exchangeren_US
dc.subjectwavy finen_US
dc.subjectdry surface of the finen_US
dc.subjectwet surface of the finen_US
dc.subjectheat transfer coefficienten_US
dc.subjectair-to-water heat exchangeren_US
dc.subjectwavy finen_US
dc.subjectdry surface of the finen_US
dc.subjectwet surface of the finen_US
dc.subjectheat transfer coefficienten_US
dc.titleExperimental analysis of fin and tube heat exchanger in heating and cooling modeen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.alternativeEnergy for buildingsen_US
dcterms.issued2017-04-28
dcterms.references13en_US
dc.description.versionTaip / Yesen_US
dc.contributor.institutionVilniaus Gedimino technikos universitetasen_US
dc.contributor.institutionVilnius Gediminas Technical Universityen_US
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineeringen_US
dc.contributor.departmentPastatų energetikos katedra / Department of Building Energeticsen_US
dcterms.sourcetitle10th International Conference “Environmental Engineering” (ICEE-2017)en_US
dc.identifier.eisbn9786094760440en_US
dc.identifier.eissn2029-7092en_US
dc.publisher.nameVilnius Gediminas Technical Universityen_US
dc.publisher.nameVilniaus Gedimino technikos universitetasen_US
dc.publisher.countryLithuaniaen_US
dc.publisher.countryLietuvaen_US
dc.publisher.cityVilniusen_US
dc.identifier.doihttps://doi.org/10.3846/enviro.2017.272en_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Kūrybinių bendrijų licencija / Creative Commons licence
Except where otherwise noted, this item's license is described as Kūrybinių bendrijų licencija / Creative Commons licence