dc.description.abstractNowadays, people are looking for solutions related to ventilation, cooling or heat demand systems, which would be energy efficient and, at the same time, would not cause the degradation of the surrounding environment. As far as ventilation is concerned, an good solution is a natural ventilation, which improves thermal comfort rooms without increasing the consumption of electrical energy in the building. In order to improve the mode of action of the natural ventilation in the building, one can mount various elements supporting the air flow. One of them is a solar chimney. In order to check the correct operation of a gravity ventilation installation in Poland’s climatic conditions, the measurements was carried out on a test stand on the 3.1 building of UTP University of Science and Technology in Bydgoszcz. The received results show the intensification of the air flow through the room the value between 50% and 150%, depending on a measuring hour (Chen et al. 2003). These research results were compared with the research results received before the installation of the solar chimney on the ducts of the gravity ventilation.en_US
dc.format.extent6 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/154497en_US
dc.rightsAttribution-NonCommercial 4.0 Internationalen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/en_US
dc.source.urihttp://enviro.vgtu.lt/index.php/enviro/2017/paper/view/437en_US
dc.subjectsolar chimneyen_US
dc.subjectnatural ventilationen_US
dc.subjectassisted gravity ventilationen_US
dc.titleEnhancement of gravity ventilation in buildingsen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.alternativeEnergy for buildingsen_US
dcterms.issued2017-04-28
dcterms.references13en_US
dc.description.versionTaip / Yesen_US
dc.type.pubtypeK1a - Monografija / Monographen_US
dc.contributor.institutionUniversity of Sciences and Technology in Bydgoszczen_US
dcterms.sourcetitle10th International Conference “Environmental Engineering” (ICEE-2017)en_US
dc.identifier.eisbn9786094760440en_US
dc.identifier.eissn2029-7092en_US
dc.publisher.nameVilnius Gediminas Technical Universityen_US
dc.publisher.nameVilniaus Gedimino technikos universitetasen_US
dc.publisher.countryLithuaniaen_US
dc.publisher.countryLietuvaen_US
dc.publisher.cityVilniusen_US
dc.identifier.doihttps://doi.org/10.3846/enviro.2017.269en_US


Šio įrašo failai

Thumbnail
Thumbnail

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą

Kūrybinių bendrijų licencija / Creative Commons licence
Išskyrus atvejus, kai nurodyta kitaip, šio įrašo licencija apibrėžiama taipKūrybinių bendrijų licencija / Creative Commons licence