dc.description.abstractFor the determination of the required embedded length for the safety against hydraulic heave several approximate solutions exist. However, most of these solutions do not take into account the geometrical boundary conditions such as width B and length L of the excavation as well as the thickness of the aquifer S. Thus, values obtained by such simplified approximate solutions can easily lead to an unsafe design. For this reason investigations on the safety against hydraulic heave have been carried out at the Chair of Geotechnical Engineering at RWTH Aachen University. From the results of numerous calculations dimensionless design charts have been generated. With the help of these design charts the required embedded length T can be determined quite easily taking into account the difference of the ground water level H, the geometrical boundary conditions of the excavation and the unity weight of submerged soil γ’.en_US
dc.description.sponsorshipDeutsches Institut für Bautechniken_US
dc.description.sponsorshipEmscher Genossenschaften_US
dc.description.sponsorshipHamburg Port Authorityen_US
dc.description.sponsorshipICG Düsseldorf GmbH & Co. KGen_US
dc.description.sponsorshipWayss & Freytag Ingenieurbau AGen_US
dc.format.extent7 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/156173en_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.source.urihttps://www.sciencedirect.com/science/article/pii/S1877705813007479en_US
dc.subjecthydraulic heaveen_US
dc.subjectfailureen_US
dc.subjectdesignen_US
dc.subjectgroundwater flowen_US
dc.subjectexcavationen_US
dc.titleDesign aid for the verification of resistance to failure by hydraulic heaveen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.accrualMethodRankinis pateikimas / Manual submissionen_US
dcterms.issued2013-05-17
dcterms.licenseCC BY NC NDen_US
dcterms.references13en_US
dc.description.versionTaip / Yesen_US
dc.type.pubtypeK1a - Monografija / Monographen_US
dc.contributor.institutionRWTH Aachen Universityen_US
dcterms.sourcetitleProcedia Engineeringen_US
dc.description.volumevol. 57en_US
dc.publisher.nameElsevieren_US
dc.publisher.countryUnited Kingdomen_US
dc.publisher.cityOxforden_US
dc.identifier.doihttps://doi.org/10.1016/j.proeng.2013.04.017en_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Kūrybinių bendrijų licencija / Creative Commons licence
Except where otherwise noted, this item's license is described as Kūrybinių bendrijų licencija / Creative Commons licence