dc.description.abstract | Earthings of the electrical power systems can achieve wide sizes. Due to equipotential bondings and a presence of main equipotential bar the earthing system can be connected even to a power transformer neutral point. Evaluation of such wide earthings for lightning protection purposes can not be easy to perform because only a part of the earthing system should be taken into account. This useful part of the earthing is described as its effective length. The paper deals with a method of effective length calculations and in order to explain the notion computer simulations and measurements of a model as well as a real earthing have been performed using impulses of 1, 4 and 10 µs front times. A good convergence investigation results have been obtained. | en_US |
dc.format.extent | 5 p. | en_US |
dc.format.medium | Tekstas / Text | en_US |
dc.language.iso | en | en_US |
dc.relation.uri | https://etalpykla.vilniustech.lt/handle/123456789/157282 | en_US |
dc.rights | Attribution 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.source.uri | http://emd.vgtu.lt/index.php/emd/emd_2012/paper/view/34.html | en_US |
dc.subject | lightning protection earthing | en_US |
dc.subject | earthing impulse impedance | en_US |
dc.subject | effective length of earthing | en_US |
dc.subject | test of earthings | en_US |
dc.title | Earthing effective length for low and high amplitudes of lightning impulse currents | en_US |
dc.type | Konferencijos publikacija / Conference paper | en_US |
dcterms.accessRights | Laisvai prieinamas / Openly available | en_US |
dcterms.accrualMethod | Rankinis pateikimas / Manual submission | en_US |
dcterms.issued | 2012-09-21 | |
dcterms.license | CC BY | en_US |
dcterms.references | 7 | en_US |
dc.description.version | Taip / Yes | en_US |
dc.contributor.institution | Gdańsk University of Technology | en_US |
dcterms.sourcetitle | 22nd International Conference “Electromagnetic Disturbances EMD’2012” | en_US |
dc.publisher.name | Vilnius Gediminas Technical University | en_US |
dc.publisher.name | Vilniaus Gedimino technikos universitetas | en_US |
dc.publisher.country | Lithuania | en_US |
dc.publisher.country | Lietuva | en_US |
dc.publisher.city | Vilnius | en_US |