dc.description.abstract | The goal of this article is to evaluate risks arising from using hot-dip galvanized reinforcement in concrete elements. The article
provides detailed summary of current experimental activities but also earlier positive remarks about applicability of hot-dip
galvanized reinforcement, mainly from the perspective of corrosion and bond strength with concrete. Based on previously
obtained data, the article disproves barrier effect of zinc coating on base steel. The reason is the initial corrosion reaction of zinc
coating in fresh concrete producing hydrogen. Further data prove that forming hydrogen irreversibly increases porosity of cement
on reinforcement/concrete interface which can significantly reduce bond strength. Sufficient filling of pores by zinc corrosion
product could not be confirmed. | en_US |
dc.description.sponsorship | GACR Agency of the Czech Republic | en_US |
dc.format.extent | 8 p. | en_US |
dc.format.medium | Tekstas / Text | en_US |
dc.language.iso | en | en_US |
dc.relation.uri | https://etalpykla.vilniustech.lt/handle/123456789/157277 | en_US |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source.uri | https://www.sciencedirect.com/science/article/pii/S1877705817305921 | en_US |
dc.subject | Hod-dip galvanized | en_US |
dc.subject | steel reinforcement | en_US |
dc.subject | concrete | en_US |
dc.subject | porosity | en_US |
dc.subject | corosion | en_US |
dc.subject | phase interface | en_US |
dc.title | Problems connected with use of hot-dip galvanized reinforcement in concrete elements | en_US |
dc.type | Konferencijos publikacija / Conference paper | en_US |
dcterms.accessRights | Laisvai prieinamas / Openly available | en_US |
dcterms.accrualMethod | Rankinis pateikimas / Manual submission | en_US |
dcterms.license | CC BY NC ND | en_US |
dcterms.references | 24 | en_US |
dc.description.version | Taip / Yes | en_US |
dc.contributor.institution | Klokner Institute of CTU | en_US |
dcterms.sourcetitle | Procedia Engineering | en_US |
dc.description.volume | vol. 172 | en_US |
dc.publisher.name | Elsevier | en_US |
dc.publisher.country | United Kingdom | en_US |
dc.publisher.city | Oxford | en_US |
dc.description.grantnumber | GACR 14-20856S | en_US |
dc.identifier.doi | https://doi.org/10.1016/j.proeng.2017.02.086 | en_US |