Show simple item record

dc.rights.licenseKūrybinių bendrijų licencija / Creative Commons licenceen_US
dc.contributor.authorTelejko, Marek
dc.date.accessioned2025-05-14T12:48:35Z
dc.date.available2025-05-14T12:48:35Z
dc.date.issued2017
dc.identifier.issn1877-7058en_US
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/157598
dc.description.abstractLow indoor air quality (IAQ) can impact occupants’ health and lead to poor productivity or low academic performance. Therefore the provision of good IAQ in classrooms and laboratories is very important. This paper presents the results of the investigation devoted to the quality of indoor air in computer laboratories of selected Polish high schools. Six schools in a town with a population of 200 000 inhabitants were involved in the investigations. The participating school buildings were built between 1975 and 1991 and had gravity ventilation systems. The variability of basic IAQ parameters, i.e., temperature, relative humidity and carbon dioxide level, was analyzed and the assessment of the computer laboratories in terms of microbiological purity was performed. The outcomes confirmed the low quality of the indoor air in these buildings. Certain modifications aimed at improving IAQ were proposed during the investigations. Two solutions were implemented. The first solution involved a twofold increase in the volume of supply air from 90 m3/h to 180 m3/h. The other modification consisted in installing indoor air cleaning devices based on the radiant catalytic ionization technology (RCI). The results of this study indicate that the proposed solution offers the potential to improve IAQ within computer labs.en_US
dc.format.extent7 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/157277en_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.source.urihttps://www.sciencedirect.com/science/article/pii/S1877705817306409en_US
dc.subjectbuilding physicsen_US
dc.subjectventilationen_US
dc.subjectair exchangeen_US
dc.subjectindoor air qualityen_US
dc.titleAttempt to improve indoor air quality in computer laboratoriesen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.accrualMethodRankinis pateikimas / Manual submissionen_US
dcterms.licenseCC BY NC NDen_US
dcterms.references18en_US
dc.description.versionTaip / Yesen_US
dc.contributor.institutionKielce University of Technologyen_US
dcterms.sourcetitleProcedia Engineeringen_US
dc.description.volumevol. 172en_US
dc.publisher.nameElsevieren_US
dc.publisher.countryUnited Kingdomen_US
dc.publisher.cityOxforden_US
dc.identifier.doihttps://doi.org/10.1016/j.proeng.2017.02.134en_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Kūrybinių bendrijų licencija / Creative Commons licence
Except where otherwise noted, this item's license is described as Kūrybinių bendrijų licencija / Creative Commons licence