dc.description.abstract | The influence of water-binder ratio on de-icing salt scaling of hardened concretes with siliceous fly ash addition is analysed in the paper.
The analysis made on the basis of 56 cycles scaling Borås test of air-entrained concretes. The levels of water-binder ratio (w/b): 0.45 and
0.38, the partial replacement of cement with fly ash (0, 20, 35, 50% mass of cement), and kind of siliceous fly ash in three categories of
loss on ignition A, B and C were variable in concrete mixes. The results show that apart from air-entraining, which was the sufficient
condition to ensure freeze-thaw resistance, also the lowest value of water-binder ratio is necessarily to ensure de-icing salt scaling
resistance of fly ash concretes. Loss on ignition of fly ash has significant influence on resistance to scaling only in air-entrained concretes
with 0.45 water-binder ratio. | en_US |
dc.format.extent | 7 p. | en_US |
dc.format.medium | Tekstas / Text | en_US |
dc.language.iso | en | en_US |
dc.relation.uri | https://etalpykla.vilniustech.lt/handle/123456789/156173 | en_US |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source.uri | https://www.sciencedirect.com/science/article/pii/S1877705813008370 | en_US |
dc.subject | air-entrained concrete | en_US |
dc.subject | scaling | en_US |
dc.subject | freeze and thaw resistance | en_US |
dc.subject | de-icing salt | en_US |
dc.subject | siliceous fly ash | en_US |
dc.subject | loss on ignition | en_US |
dc.title | Water-binder ratio influence on de-icing salt scaling of fly ash concretes | en_US |
dc.type | Konferencijos publikacija / Conference paper | en_US |
dcterms.accessRights | Laisvai prieinamas / Openly available | en_US |
dcterms.accrualMethod | Rankinis pateikimas / Manual submission | en_US |
dcterms.issued | 2013-05-17 | |
dcterms.license | CC BY NC ND | en_US |
dcterms.references | 23 | en_US |
dc.description.version | Taip / Yes | en_US |
dc.contributor.institution | Cracow University of Technology | en_US |
dcterms.sourcetitle | Procedia Engineering | en_US |
dc.description.volume | vol. 57 | en_US |
dc.publisher.name | Elsevier | en_US |
dc.publisher.country | United Kingdom | en_US |
dc.publisher.city | Oxford | en_US |
dc.identifier.doi | https://doi.org/10.1016/j.proeng.2013.04.104 | en_US |