Rodyti trumpą aprašą

dc.contributor.authorJakimavičiūtė-Maselienė, Vaidotė
dc.contributor.authorMažeika, Jonas
dc.contributor.authorPetrošius, Rimantas
dc.contributor.authorSkuratovič, Zana
dc.date.accessioned2026-04-14T10:10:45Z
dc.date.available2026-04-14T10:10:45Z
dc.date.issued2011
dc.identifier.isbn9789955288268en_US
dc.identifier.issn2029-7106en_US
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/160237
dc.description.abstractIAEA safety documents (Safety standarts… 1994; 1999a; 1999b) recommend assessing the safety framework of groundwater exploitation in the proximity of nuclear facilities. The main task of this study is to assess the results on the re-calculation of Visaginas town wellfield well protection zones (WPZ), since the Visaginas town wellfield is installed close to Ignalina Nuclear Power Plant (INPP) site and other sites of existing or planed new nuclear facilities. The numerical model used in this study is based on three-dimensional finite-element code FEFLOW 5.0 which allows modeling of groundwater flow and contaminant transport in a layered three-dimensional system. The calibrated model of Visaginas wellfield area simulated the groundwater flow in the Quaternary and Upper-Middle Devonian aquifers systems. The evaluation of well protection zones for wellfields exploiting groundwater is currently determined by the Lithuanian legal documents (HN 44:2006). As a result of modeling the groundwater formation sources were specified and dimensions of wells protection zones in sectors 3a and 3b were established. The groundwater modeling results of this study shows that the third sub-zone (3b) of WPZ should be 0.61.1 km away from the wellfield fence. The long axis of WPZ extends for 4 250 m from north to south and for approximately 3 250 m from east to west. Visaginas wellfield capture zone during 50 years operation would reach the site for planned near-surface repository for radioactive waste in case of hypothetical very high wellfield capacity more than 70 000 m3/day.en_US
dc.format.extent7 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/160185en_US
dc.source.urihttp://enviro2011.vgtu.lt/Abstracts/1/023.htmlen_US
dc.subjectwellfielden_US
dc.subjectcapture zoneen_US
dc.subjectaquiferen_US
dc.subjectfinite elements modelen_US
dc.titleHydrogeology model of Ignalina region for Visaginas well field protection zone substantiationen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.accrualMethodRankinis pateikimas / Manual submissionen_US
dcterms.alternativeEnvironmental Protectionen_US
dcterms.issued2011-05-20
dcterms.references18en_US
dc.description.versionTaip / Yesen_US
dc.contributor.institutionNature Research Centreen_US
dc.contributor.institutionVilniaus Gedimino technikos universitetasen_US
dc.contributor.institutionVilnius Gediminas Technical Universityen_US
dcterms.sourcetitle8th International Conference “Environmental Engineering” (ICEE-2011)en_US
dc.identifier.eisbn9789955288275en_US
dc.identifier.eissn2029-7092en_US
dc.publisher.nameVilnius Gediminas Technical Universityen_US
dc.publisher.nameVilniaus Gedimino technikos universitetasen_US
dc.publisher.countryLithuaniaen_US
dc.publisher.countryLietuvaen_US
dc.publisher.cityVilniusen_US


Šio įrašo failai

Thumbnail

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą